The Omron HEM-711 is a fully automatic digital blood pressure monitor for upper arm measurement. It features IntelliSense technology for accurate readings, one-touch operation, a large LCD display with date/time, hypertension indicator, irregular heartbeat detector, memory storage for up to 14 readings, and body movement detection. Powered by 4 AA batteries or AC adapter (optional). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, Arm cuff, AC adapter port, Battery compartment, START/STOP button, Memory button, LCD display.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for accurate reading |
| One-Touch Operation | Simple START/STOP button for easy use |
| Hypertension Indicator | Displays symbol if reading exceeds WHO guidelines |
| Irregular Heartbeat Detector | Detects and displays symbol for irregular heartbeats during measurement |
| Body Movement Detection | Alerts if movement is detected during measurement |
| 14 Memory Storage | Stores up to 14 readings with date and time |
| Large LCD Display | Clear display of systolic/diastolic pressure and pulse rate |
| Cuff Wrap Guide | Indicates proper cuff placement |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes of inactivity |
| AC Adapter Compatible | Optional AC adapter for continuous use |
Read all instructions before use. Consult physician for proper monitoring.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician.
Front: LCD display, START/STOP button, Memory button. Side: AC adapter port. Bottom: Battery compartment. Cuff: Air tube, Velcro fastener, artery marker.
Prepare monitor for first use.
NOTE: Use correct cuff size (22-32 cm arm circumference). Incorrect size affects accuracy.
Follow these steps for accurate readings.
Tip: Take measurements at same time daily for consistent tracking.
LCD shows: Systolic pressure (upper number), Diastolic pressure (lower number), Pulse rate, Date/Time, Memory number, Hypertension indicator (if systolic ≥135 or diastolic ≥85), Irregular heartbeat symbol (if detected), Body movement symbol (if detected), Low battery icon, Cuff wrap guide.
Stores last 14 readings with date and time.
Note: Memory is retained when batteries are removed (for approx. 5 minutes).
Clean with soft, dry cloth. Do not immerse in water or use chemicals.
CAUTION! Do not disassemble or attempt repairs. Contact authorized service.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries. |
| Error "E" appears | Cuff not attached properly | Check cuff connection; reattach securely. |
| Inconsistent readings | Body movement, incorrect cuff position | Remain still; reposition cuff at heart level. |
| Memory not working | Batteries removed too long | Memory cleared; reset date/time. |
| Monitor doesn't inflate | Blocked air tube, low batteries | Check tube for kinks; replace batteries. |
| Irregular heartbeat symbol | Arrhythmia detected | Consult physician if symbol appears frequently. |
Reset: Remove batteries for 5 minutes, then reinsert.
Service: Contact Omron Healthcare: 1-800-634-4350 or www.omronhealthcare.com