Omron Wrist Blood Pressure Monitor 652 Manual

The Omron Wrist Blood Pressure Monitor 652 is a clinically validated, automatic wrist monitor designed for convenient at-home blood pressure measurement. It features IntelliSense technology for accurate readings, a large LCD display, memory storage for multiple users, hypertension detection, irregular heartbeat detection, and body movement detection. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. First-Time Setup 4. Specifications 5. Controls and Display 6. Taking a Measurement 7. Memory Function 8. Care & Maintenance 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Wrist Cuff with position sensor, Monitor Unit, Storage Case, Instruction Manual, and 2 AAA batteries.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for accurate readings
Body Movement DetectionAlerts if movement is detected during measurement
Irregular Heartbeat DetectionDetects and displays irregular heartbeat symbol
Hypertension IndicatorHighlights readings above normal range
Dual User MemoryStores up to 60 readings per user (120 total)
Date & Time StampRecords measurement date and time
Average ReadingCalculates average of last 3 readings
Automatic Power OffConserves battery life
Wrist Position SensorEnsures proper positioning for accurate results
Large LCD DisplayEasy-to-read results and icons

Safety Precautions

Read all instructions before use. Consult your physician for proper monitoring.

  1. Do not use on infants, children, or persons unable to express themselves.
  2. Do not use during bathing or showering.
  3. Do not wrap cuff over clothing; apply directly to bare wrist.
  4. Do not use if monitor or cuff is damaged.
  5. Keep away from electromagnetic fields (microwaves, mobile phones).

WARNING! This device is not a substitute for professional medical diagnosis. Always follow your doctor's instructions.

First-Time Setup

Prepare monitor for first use.

  1. Insert batteries: Open battery compartment, insert 2 AAA batteries observing polarity.
  2. Set date and time: Press SET button, use START/STOP to adjust values.
  3. Select user: Press USER button to choose User 1 or User 2.
  4. Apply cuff: Position on left wrist (unless instructed otherwise by physician).

CAUTION! Ensure wrist is at heart level during measurement for accurate readings.

Specifications

Controls and Display

Front Panel: START/STOP button, SET button, USER button, Memory button.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator (1/2), Date/Time, Battery indicator, Heart symbol (irregular heartbeat), Movement symbol, Hypertension indicator, Memory average, Morning/Evening indicator.

Settings: Date/Time setup, User selection, Memory recall, Average calculation.

Taking a Measurement

For accurate results, follow these steps carefully.

  1. Rest for 5 minutes before measuring.
  2. Sit comfortably with feet flat on floor.
  3. Place cuff on left wrist, 1-2 cm above wrist bone.
  4. Position wrist at heart level (use position sensor indicator).
  5. Press START/STOP button to begin inflation.
  6. Remain still and quiet during measurement.
  7. Read results on display when measurement completes.
  8. Press START/STOP to turn off or wait for auto power-off.

Tip: Take measurements at the same time each day for consistent tracking.

Memory Function

Store and review past measurements.

  1. Select user: Press USER button to choose User 1 or User 2.
  2. View memory: Press MEMORY button to scroll through stored readings.
  3. View average: Hold MEMORY button for 3 seconds to see average of last 3 readings.
  4. Clear memory: In memory mode, press SET and START/STOP simultaneously for 3 seconds.

Note: Memory is preserved when batteries are replaced if done within 3 minutes.

Care & Maintenance

Clean monitor with soft, dry cloth. Do not use water, solvents, or abrasive cleaners.

  1. Remove batteries if not using for extended period.
  2. Store in provided case in cool, dry place.
  3. Avoid extreme temperatures, humidity, dust, and direct sunlight.
  4. Replace cuff if it becomes damaged or stiff.

CAUTION! Never immerse monitor in water or other liquids.

Regulatory Information

FDA Cleared: K number [insert if applicable]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350. This device complies with Part 15 of FCC Rules.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace with new AAA batteries.
Error E1 displayedCuff not properly wrappedReapply cuff correctly and retry.
Error E2 displayedMovement during measurementRemain still and retry measurement.
Error E3 displayedPulse too weak or irregularRest 5 minutes and retry. Consult physician if persistent.
Inconsistent readingsImproper positioningEnsure wrist is at heart level during measurement.
Memory lostBatteries removed too longReplace batteries within 3 minutes to preserve memory.
Cuff doesn't inflateBlocked air tube or leakCheck tube connections; ensure cuff is not twisted.

Reset: Remove batteries for 1 minute, then reinsert.

Service: 1-800-634-4350; www.omronhealthcare.com