Omron Wrist Blood Pressure Monitor 629 Manual

The Omron Wrist Blood Pressure Monitor 629 is a compact, automatic device for measuring blood pressure and pulse rate at the wrist. It features IntelliSense technology for accurate readings, a large LCD display, memory storage for up to 60 readings, hypertension indicator, irregular heartbeat detector, body movement detection, and date/time stamp. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Device Components 4. Specifications 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Battery Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Wrist cuff, Storage case, Instruction manual, 2 AAA batteries.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for accurate readings
Memory StorageStores up to 60 readings with date and time stamp
Hypertension IndicatorDisplays warning symbol if reading exceeds normal range
Irregular Heartbeat DetectorDetects and displays irregular heartbeat during measurement
Body Movement DetectionAlerts if movement is detected during measurement
Large LCD DisplayEasy-to-read results for systolic, diastolic, pulse, and date/time
Automatic Power OffConserves battery life by turning off after 1 minute of inactivity
Wrist CuffFits wrists 5.3 to 7.1 inches (13.5 to 18.0 cm) in circumference
START/STOP ButtonInitiates and stops measurement
MEMORY ButtonRecalls stored readings

Safety Precautions

Read all instructions before use.

  1. Do not use on infants, children, or persons unable to express themselves.
  2. Consult physician before use if you have arrhythmia, blood circulation problems, or other medical conditions.
  3. Do not use during or immediately after physical exercise, bathing, eating, or drinking alcohol/caffeine.
  4. Ensure cuff is positioned correctly at heart level.

WARNING! This device is not a substitute for professional medical diagnosis. Seek medical advice for health concerns.

Device Components

Identify all parts before use.

  1. Main Unit: Houses display, buttons, and internal pump.
  2. Wrist Cuff: Wraps around wrist with Velcro closure.
  3. LCD Display: Shows measurements, indicators, and date/time.
  4. START/STOP Button: Starts and stops measurement.
  5. MEMORY Button: Recalls stored readings.
  6. SET Button: Sets date and time.
  7. Battery Compartment: Holds 2 AAA batteries.
  8. Storage Case: Protects device when not in use.

CAUTION! Do not disassemble or modify the device.

Specifications

Initial Setup

Prepare device for first use.

  1. Insert Batteries: Open compartment, insert 2 AAA batteries observing polarity.
  2. Set Date/Time: Press SET button, use START/STOP to adjust, press SET to confirm.
  3. Apply Cuff: Place on left wrist (unless instructed otherwise by physician).
  4. Positioning: Sit quietly for 5 minutes before first measurement.

Tip: Ensure batteries are fresh for accurate readings.

Taking a Measurement

Follow these steps for accurate readings.

  1. Rest: Sit quietly for 5 minutes in a chair with feet flat on floor.
  2. Position: Place cuff on bare left wrist 0.5-1 inch above wrist bone.
  3. Align: Position device so display faces upward and cuff aligns with middle finger.
  4. Raise to Heart Level: Rest elbow on table, raise wrist to heart level.
  5. Start: Press START/STOP button. Cuff will inflate automatically.
  6. Remain Still: Keep still and quiet until measurement completes.
  7. Read Results: Systolic, diastolic, and pulse appear on display.
  8. Store: Reading is automatically stored in memory.

WARNING! Do not move or talk during measurement.

Memory Function

Device stores last 60 readings.

  1. Recall: Press MEMORY button to display stored readings.
  2. Scroll: Press START/STOP to scroll through readings (newest to oldest).
  3. Exit: Press MEMORY again or wait 1 minute to return to standby.
  4. Clear Memory: To clear all readings, remove batteries for 1 minute.

Note: Date and time stamp helps track readings over time.

Understanding Results

Interpret display symbols and readings.

SymbolMeaning
SYSSystolic pressure (higher number)
DIADiastolic pressure (lower number)
PulseHeart rate in beats per minute
Hypertension IndicatorFlashing if reading exceeds 135/85 mmHg
Irregular Heartbeat SymbolAppears if irregular rhythm detected
Body Movement SymbolAppears if movement detected; retake measurement
Low Battery SymbolIndicates batteries need replacement

Consult Physician: For interpretation of readings and health advice.

Care & Maintenance

Keep device clean and functional.

  1. Cleaning: Wipe cuff and unit with soft, dry cloth. Do not immerse in water.
  2. Storage: Keep in storage case in cool, dry place away from direct sunlight.
  3. Cuff Care: Do not fold tightly or expose to sharp objects.
  4. Inspection: Check for cracks or damage before each use.

CAUTION! Do not use alcohol, benzene, or abrasive cleaners.

Battery Information

Power management for extended use.

  1. Battery Type: 2 AAA alkaline batteries (LR03).
  2. Installation: Match + and - symbols in compartment.
  3. Low Battery: Symbol appears when batteries are weak.
  4. Replacement: Replace both batteries at same time.
  5. Disposal: Dispose according to local regulations.

Note: Remove batteries if device will not be used for 3 months or longer.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace both AAA batteries.
Error E1Cuff not wrapped correctlyRewrap cuff snugly and retry.
Error E2Movement during measurementKeep still and retake measurement.
Error E3Pulse too irregular/weakRest 5 minutes and retry; consult physician if persistent.
Inaccurate readingIncorrect positioningEnsure wrist is at heart level; follow measurement steps.
Memory not workingBattery removalMemory clears if batteries removed >1 minute; replace batteries.
Cuff does not inflateBlockage or batteryCheck for cuff twists; replace batteries.

Reset: Remove batteries for 1 minute to reset device.

Service: For repairs, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com.