The Omron Series 10 BP7450 is a digital automatic blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a large LCD display, one-touch operation, memory storage for multiple users, irregular heartbeat detection, hypertension indicator, and body movement detection. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff, AC adapter port, Battery compartment, START/STOP button, Memory button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Large LCD Display | Shows systolic/diastolic pressure, pulse rate, and indicators |
| Memory Function | Stores readings for 2 users (up to 100 readings each) |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Highlights readings above WHO hypertension thresholds |
| Body Movement Detection | Alerts if movement is detected during measurement |
| AC Adapter Port | For power connection (adapter sold separately) |
| Battery Compartment | Holds 4 AA batteries |
| START/STOP Button | Starts and stops measurement |
| Memory Button | Accesses stored readings |
Unpack and inspect contents. Place on stable surface.
WARNING! Do not use if cuff is damaged. Ensure cuff is correctly positioned for accurate readings.
Power on monitor; follow initial setup.
CAUTION! Remain still and quiet during measurement. Do not talk or move arm.
Access functions via front panel buttons. START/STOP: Begin/end measurement. MEMORY: View stored readings, set date/time.
Display Indicators: Systolic/Diastolic pressure, Pulse rate, User icon, Battery indicator, Irregular heartbeat symbol, Hypertension indicator, Date/Time.
Settings: Date/Time format (MM/DD or DD/MM), User selection (1 or 2). Measurement: Automatic inflation/deflation, average of last 3 readings display.
Use optional AD-A15170L AC adapter.
Tip: Use AC adapter for extended use to conserve batteries.
For accurate readings, follow proper procedure.
WARNING! Do not use on injured or sore arm. Consult doctor for medical diagnosis.
View and manage stored readings.
Note: Memory clears separately for each user.
Remove batteries before cleaning. Use soft, dry cloth only; do not use liquids or solvents.
CAUTION! Do not immerse in water. Avoid extreme temperatures and humidity. Store in provided case.
FDA Cleared: K993522. CE Marked: Meets EU medical device directive 93/42/EEC. Manufacturer: Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries; ensure correct polarity. |
| Error E1 displayed | Cuff not attached properly | Check cuff connection; reattach securely. |
| Error E2 displayed | Movement during measurement | Remain still; retake measurement. |
| Inconsistent readings | Incorrect cuff position | Reposition cuff 1-2 cm above elbow at heart level. |
| Memory not storing | Memory full | Clear memory for current user. |
Reset: Remove batteries for 1 minute to reset system.
Service: 1-800-634-4350; www.omronhealthcare.com