The Omron Model BP786N is an upper arm blood pressure monitor with IntelliSense technology, irregular heartbeat detection, hypertension indicator, 200-memory storage with date and time, body movement detection, and a wide-range D-Ring cuff (22-42 cm). It features a large LCD display, one-touch operation, and is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, D-Ring cuff, AC adapter (optional), instruction manual, storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol during measurement |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| 200-Memory Storage | Stores up to 200 readings with date and time stamp |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| Wide-Range D-Ring Cuff | Fits arm circumferences 22-42 cm (9-17 inches) |
| Large LCD Display | Easy-to-read backlit display with clear icons |
| One-Touch Operation | Simple START/STOP button for easy use |
| Clinically Validated | Meets accuracy standards of major health organizations |
| AC Adapter Compatible | Optional adapter for continuous use (model EA11A) |
Front Panel: LCD display, START/STOP button, MEMORY button, TIME SET button.
WARNING! Do not disassemble the unit. Keep away from children.
Before first use: Install batteries or connect AC adapter, set date/time.
CAUTION! Use correct cuff size. Incorrect fit affects accuracy.
Proper measurement technique ensures accurate results.
Tip: Take measurements at same time daily for consistent tracking.
Display icons and their meanings:
| Icon | Meaning |
|---|---|
| Heart with ! | Irregular heartbeat detected |
| Exclamation mark | Body movement detected |
| Up arrow | Hypertension indicator (high reading) |
| Memory symbol | Reading stored in memory |
| Clock | Date/time displayed with reading |
Normal Ranges: Systolic: Below 120 mmHg; Diastolic: Below 80 mmHg. Consult physician for interpretation.
Stores 200 readings with date/time stamp.
Note: Memory is retained when batteries are removed.
Proper care ensures longevity and accuracy.
CAUTION! Never immerse unit in water. Do not attempt repairs.
FDA Cleared: K number [insert if applicable]. CE Marked: Meets European Medical Device Directive requirements. Manufactured by Omron Healthcare, Inc. For support in US/Canada: 1-800-634-4350. International: visit www.omronhealthcare.com. This device complies with Part 15 of FCC Rules. Copyright © Omron Healthcare, Inc. All rights reserved.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries with new ones. |
| Error E1, E2, E3 | Cuff not wrapped properly | Rewrap cuff correctly, ensure tube is connected. |
| Inconsistent readings | Body movement, talking | Remain still and quiet during measurement. |
| Cuff does not inflate | Air leak, tube blockage | Check tube connections, ensure cuff is not torn. |
| Memory not working | Memory full or corrupted | Clear memory or replace batteries. |
| Irregular heartbeat symbol always on | Actual irregular heartbeat | Consult physician for evaluation. |
Reset: Remove batteries for 5 minutes, then reinstall.
Service: 1-800-634-4350 (US/Canada); www.omronhealthcare.com