Omron Model BP786N Instruction Manual

The Omron Model BP786N is an upper arm blood pressure monitor with IntelliSense technology, featuring a ComFit cuff, hypertension indicator, irregular heartbeat detector, multi-user memory (up to 100 readings per user), date/time stamp, WHO classification indicator, body movement detection, and AC adapter compatibility. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Display 6. Taking Measurements 7. Memory Function 8. Care & Maintenance 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, ComFit cuff, AC adapter, storage case, instruction manual.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for comfortable measurement
ComFit CuffPre-formed cuff (22-42 cm) for easy self-application
Hypertension IndicatorDisplays warning symbol if reading exceeds 135/85 mmHg
Irregular Heartbeat DetectorDetects and displays irregular heartbeat during measurement
Multi-User MemoryStores up to 100 readings for each of two users
WHO Classification IndicatorShows blood pressure category based on WHO standards
Date/Time StampRecords date and time of each reading
Body Movement DetectionAlerts if movement is detected during measurement
AC Adapter PortFor powering device without batteries
START/STOP ButtonInitiates and stops blood pressure measurement

Installation & Setup

Unpack and inspect contents. Ensure all parts are present.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter (optional): Plug adapter into DC jack and wall outlet.
  3. Set date and time: Press SET button, use arrow keys to adjust.
  4. Attach cuff: Connect air plug to main unit until it clicks.

WARNING! Do not use if cuff is damaged. Keep away from children.

First-Time Use

Prepare for accurate measurement.

  1. Rest for 5 minutes before measurement.
  2. Sit comfortably with feet flat on floor, back supported.
  3. Apply cuff to bare upper arm 1-2 cm above elbow.
  4. Position cuff at heart level.
  5. Press START/STOP to begin measurement.

CAUTION! Do not move or talk during measurement. Avoid taking measurements after eating, bathing, or exercising.

Specifications

Controls and Display

Front Panel: START/STOP button, SET button, UP/DOWN arrows, MEMORY button.

Display Symbols: User indicator (1/2), battery icon, date/time, systolic/diastolic pressure, pulse rate, hypertension indicator, irregular heartbeat symbol, body movement alert, WHO classification bar.

Settings Menu: Press SET to access date/time, user selection, memory review, unit selection (mmHg/kPa).

Taking Measurements

Follow proper procedure for accurate results.

  1. Select user: Press SET, choose User 1 or User 2.
  2. Apply cuff correctly: Ensure index line is within range marks.
  3. Press START/STOP: Cuff inflates automatically.
  4. Remain still: Keep arm relaxed at heart level.
  5. Read results: Systolic, diastolic, and pulse display when complete.
  6. Cuff deflates: Remove cuff after measurement.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Stores and reviews previous readings.

  1. View memory: Press MEMORY button to scroll through stored readings.
  2. Check average: Display shows average of last 3 readings for current user.
  3. Clear memory: In settings menu, select "Clear All Memory" option.
  4. Date/Time stamp: Each reading includes measurement timestamp.

Note: Memory is maintained when batteries are replaced if done within 3 minutes.

Care & Maintenance

Unplug AC adapter and remove batteries before cleaning. Use soft, dry cloth only.

  1. Clean cuff: Wipe with damp cloth, air dry completely.
  2. Clean unit: Use dry cloth; avoid liquids.
  3. Store properly: Keep in storage case in cool, dry place.
  4. Replace batteries: When battery icon appears low.

CAUTION! Do not immerse in water. Do not use alcohol or solvents.

Regulatory Information

FDA Cleared: KXXXXXX. CE Marked: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 AA batteries; check polarity.
Error code E1Cuff not attached properlyReconnect cuff; ensure plug is fully inserted.
Error code E2Cuff over-inflatedDeflate completely; restart measurement.
Inconsistent readingsBody movement during measurementRemain still; retake measurement.
Memory not savingMemory fullClear old readings; memory stores 100 per user.
Irregular heartbeat symbolPossible arrhythmia detectedConsult healthcare provider if symbol appears frequently.

Reset: Remove batteries for 3 minutes to reset device.

Service: 1-800-634-4350; www.omronhealthcare.com