The Omron Model BP760N is an automatic upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a wide-range D-Ring cuff (22-42 cm), hypertension indicator, irregular heartbeat detector, body movement detection, 100-memory storage with date/time stamp, averaging of last 3 readings, and WHO classification indicator. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, D-Ring cuff, AC adapter, storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| D-Ring Cuff | Pre-formed cuff for easy self-application (22-42 cm circumference) |
| Hypertension Indicator | Displays warning symbol if reading exceeds 135/85 mmHg |
| Irregular Heartbeat Detector | Detects pulse irregularities during measurement |
| Body Movement Detection | Alerts if movement affects accuracy |
| 100-Memory Storage | Stores readings with date and time stamp |
| Average of Last 3 Readings | Calculates average of most recent measurements |
| WHO Classification Indicator | Shows blood pressure category based on WHO standards |
| Clock Function | Built-in clock for time-stamping measurements |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes |
Read all instructions before use.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician about blood pressure readings.
Prepare for accurate measurement.
CAUTION! Rest for 5 minutes before measuring. Avoid eating, smoking, or exercising 30 minutes prior.
Front Panel: START/STOP button, SET button, MEMORY button.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, Battery indicator, Memory number, Date/Time, Hypertension indicator, Irregular heartbeat symbol, Body movement warning, WHO classification bar, Average icon.
Settings: Press SET to adjust date/time. Press MEMORY to review stored readings. Press START/STOP to begin/stop measurement.
Follow these steps for accurate results.
Tip: Take measurements at same time each day for consistent tracking.
Stores 100 readings with date/time.
Note: Memory is retained when batteries are replaced if done within 3 minutes.
WHO Classification Indicator shows color-coded categories:
| Category | Systolic (mmHg) | Diastolic (mmHg) | Display Color |
|---|---|---|---|
| Optimal | < 120 | < 80 | Green |
| Normal | 120-129 | 80-84 | Light Green |
| High Normal | 130-139 | 85-89 | Yellow |
| Hypertension | ≥ 140 | ≥ 90 | Red |
Irregular Heartbeat Symbol: Appears if irregular pulse detected during measurement. Consult physician if frequent.
Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.
CAUTION! Do not disassemble or attempt repairs. No user-serviceable parts inside.
FDA Cleared: KXXXXXX. CE Marked: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © 2023 Omron Healthcare. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries; ensure proper orientation. |
| Error E1 | Cuff not wrapped correctly | Rewrap cuff; ensure artery marker aligned properly. |
| Error E2 | Excessive movement during measurement | Remain still; retake measurement. |
| Error E3 | Pulse too weak or irregular | Reposition cuff; ensure proper fit; consult physician. |
| Inconsistent readings | Incorrect posture or timing | Follow preparation guidelines; wait 2-3 minutes between readings. |
| Cuff doesn't inflate | Air leak or blockage | Check tubing connections; ensure cuff not twisted. |
| Memory not working | Batteries removed too long | Replace batteries within 3 minutes to retain memory. |
Reset: Remove batteries for 5 minutes, then reinstall.
Service: 1-800-634-4350; www.omronhealthcare.com