The Omron Model BP7450 is an upper arm blood pressure monitor with IntelliSense technology, irregular heartbeat detection, hypertension indicator, body movement detection, 2-user memory with 100 readings each, date and time display, and one-touch operation. It features a large backlit LCD display, adjustable cuff (22-42 cm), and is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, adjustable arm cuff, AC adapter port, battery compartment, START/STOP button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Displays symbol if systolic/diastolic readings are high |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| 2-User Memory | Stores 100 readings per user with date and time |
| Large Backlit LCD | Easy-to-read display with backlight for low-light conditions |
| Adjustable Cuff | Fits arm circumferences 22-42 cm (9-17 inches) |
| One-Touch Operation | Simple START/STOP button for easy use |
| Clinically Validated | Meets accuracy standards of major health organizations |
| Power Options | 4 AA batteries or AC adapter (included) |
Unpack and verify all components are present.
WARNING! Do not use if any components are damaged or missing. Contact customer support.
Prepare monitor for first use.
CAUTION! Use only recommended batteries and AC adapter. Do not mix old and new batteries.
Front Panel: START/STOP button, USER button, CLOCK button, SET button.
Display Symbols: User indicator (1/2), systolic/diastolic pressure, pulse rate, date/time, battery indicator, irregular heartbeat symbol, hypertension indicator, body movement detection, memory recall, average reading.
Settings: Date/time adjustment, memory recall, user selection, average calculation (last 3 readings per user).
For accurate readings, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
Stores 100 readings per user with date and time.
Note: Memory is maintained when batteries are removed (for approximately 3 minutes).
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not immerse in water or use abrasive cleaners. Keep away from children.
FDA Cleared: K012456. This device complies with Part 15 of FCC Rules. CE Marked: Meets European Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd., Japan. For support in US/Canada: 1-800-634-4350. International: www.omronhealthcare.com. Copyright © Omron Healthcare, Inc. All rights reserved.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries; ensure proper polarity. |
| Error code E1 | Cuff not attached properly | Ensure cuff tube is fully inserted into connector. |
| Error code E2 | Cuff overinflated | Remove cuff and restart measurement. |
| Error code E3 | Irregular heartbeat detected | Measurement completed but consult healthcare provider if frequent. |
| Inconsistent readings | Improper positioning | Ensure cuff at heart level; rest 5 minutes before measuring. |
| Memory not saving | User not selected | Press USER button to select User 1 or User 2 before measurement. |
| Cuff too tight/loose | Wrong size | Verify arm circumference (22-42 cm); use appropriate cuff. |
| Body movement symbol | Movement during measurement | Remain still and quiet; retake measurement. |
Reset: Remove batteries for 3 minutes to reset all settings.
Service: 1-800-634-4350; www.omronhealthcare.com