Omron Model BP629 Manual

The Omron Model BP629 is an upper arm blood pressure monitor designed for home use, featuring IntelliSense technology for accurate and comfortable readings, hypertension indicator, irregular heartbeat detection, body movement detection, memory storage for multiple users, and a large LCD display with backlight. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Parts Identification 4. Specifications 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. Understanding the Display 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Arm cuff with D-ring, AC adapter port, Memory button, START/STOP button, User selection buttons (1 & 2).

FeatureDescription
IntelliSense TechnologyAutomatically adjusts cuff pressure for accurate and comfortable measurement
Hypertension IndicatorDisplays warning symbol if reading is above standard levels
Irregular Heartbeat DetectionDetects and displays symbol for irregular heartbeats during measurement
Body Movement DetectionAlerts user if movement is detected during measurement
Dual User MemoryStores up to 100 readings for each of two users
Large LCD with BacklightEasy-to-read display for day or night use
Average ReadingCalculates average of last three readings taken in the same mode
AC Adapter PortFor powering the device (adapter sold separately)
Date & Time DisplayShows date and time with stored readings
Automatic Power OffConserves battery life by turning off after 2 minutes of inactivity

Safety Precautions

Before using the device, read all safety instructions carefully.

  1. Do not use on infants, young children, or persons who cannot express themselves.
  2. Do not use during or immediately after physical exercise or bathing.
  3. Do not wrap cuff over clothing; ensure cuff is applied directly to bare skin.
  4. Do not use the monitor if you suspect it is damaged or malfunctioning.
  5. Keep the monitor away from children and pets.

WARNING! This device is for home use only and is not intended for medical diagnosis. Consult your physician for interpretation of readings.

Parts Identification

Front Panel: LCD Display, START/STOP button, Memory button, User buttons (1 & 2). Side: AC adapter port. Cuff: Arm cuff with air tube, D-ring fastener, artery mark.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator, Memory full, Hypertension indicator, Irregular heartbeat, Body movement, Low battery, Date/Time.

Specifications

Initial Setup

Before first use, install batteries and set date/time.

  1. Insert Batteries: Open battery compartment on back, insert 4 AA batteries matching polarity.
  2. Set Date/Time: Press and hold Memory button for 3 seconds. Use START/STOP to adjust values, Memory to confirm and move to next setting.
  3. Apply Cuff: Sit quietly for 5 minutes before first measurement. Wrap cuff on left arm (unless instructed otherwise by physician) with artery mark over brachial artery.

CAUTION! Use only recommended batteries or AC adapter. Do not mix old and new batteries.

Taking a Measurement

For accurate readings, follow these steps carefully.

  1. Sit comfortably with feet flat on floor, back supported, and arm resting on table at heart level.
  2. Select User: Press User 1 or User 2 button. Corresponding symbol will appear on display.
  3. Apply cuff correctly: Insert end through D-ring, snug but not tight (allow one finger underneath).
  4. Press START/STOP: Cuff will inflate automatically. Remain still and quiet during measurement.
  5. Reading Displayed: Results (systolic/diastolic pressure and pulse) appear on screen. Cuff deflates automatically.
  6. Memory Storage: Reading is automatically stored for selected user.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

View, recall, or delete stored readings.

  1. View Memory: Press Memory button. Most recent reading for selected user appears.
  2. Scroll Through Memory: Press START/STOP to scroll through stored readings in reverse chronological order.
  3. View Average: While in memory mode, press and hold Memory button for 3 seconds to display average of last three readings.
  4. Delete All Memory: With device off, press and hold both User 1 and User 2 buttons, then press START/STOP. "CLr" appears, then all memory is cleared.

Note: Memory is maintained when batteries are removed.

Understanding the Display

Symbols and indicators on the LCD screen.

SymbolMeaning
User 1 / User 2Indicates which user profile is active
Memory FullAppears when memory for selected user is full (100 readings)
Hypertension IndicatorFlashing symbol appears if reading exceeds 135/85 mmHg
Irregular HeartbeatAppears if irregular heartbeat is detected during measurement
Body MovementAppears if excessive movement is detected; measurement may be inaccurate
Low BatteryAppears when battery power is low; replace batteries soon
Date & TimeDisplayed with stored readings in memory mode

Care & Maintenance

Proper care ensures accurate measurements and long device life.

  1. Cleaning: Wipe main unit and cuff with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.
  2. Storage: Store in cool, dry place away from direct sunlight, extreme temperatures, and high humidity.
  3. Cuff Care: Do not fold cuff tightly or bend air tube sharply. Do not wash cuff.
  4. Batteries: Remove batteries if device will not be used for 3 months or more.

CAUTION! Never immerse device in water or other liquids. Do not disassemble or attempt repairs.

Regulatory Information

FDA Cleared: This device complies with FDA regulations for home blood pressure monitors. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No display when START pressedDead batteriesReplace all 4 AA batteries with new ones.
Error "E" appearsCuff not wrapped correctlyRewrap cuff, ensuring artery mark is positioned correctly.
Inconsistent readingsBody movement during measurementRemain still and quiet; avoid talking during measurement.
Memory full indicator100 readings stored for userDelete some or all memory readings.
Irregular heartbeat symbolPossible arrhythmia detectedConsult your physician if symbol appears frequently.
Cuff does not inflateAir tube not connected properlyCheck connection between cuff and main unit.

Reset: Remove batteries for 2 minutes, then reinsert to reset device.

Service: 1-800-634-4350; www.omronhealthcare.com