The Omron Model BP 7250 is an upper arm blood pressure monitor with IntelliSense technology, irregular heartbeat detection, hypertension indicator, 200-memory storage with date and time stamp, body movement detection, and a large backlit display. It features one-touch operation, automatic inflation, and is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Upper Arm Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatic inflation to optimal pressure for comfort |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Displays symbol if reading is above hypertension threshold |
| 200-Memory Storage | Stores readings with date and time stamp for two users |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Large Backlit Display | Easy-to-read LCD with backlight for low-light conditions |
| One-Touch Operation | Start measurement with a single button press |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes of inactivity |
| Cuff Wrap Guide | Indicates proper cuff placement on the display |
| Date & Time Stamp | Records measurement time for tracking trends |
Unpack and inspect all contents. Ensure device is on a stable surface.
WARNING! Use only specified batteries and adapter. Do not use near flammable gases.
Power on device; follow proper measurement procedure.
CAUTION! Do not take measurements immediately after exercise, eating, or bathing. Rest for 5 minutes.
Front Panel: START/STOP button, MEMORY button, SET button. Display Icons: Systolic/Diastolic, Pulse, Irregular Heartbeat, Hypertension, User Indicator, Memory, Cuff Guide, Low Battery, Date/Time.
Button Functions: START/STOP: Begin/end measurement. MEMORY: Review stored readings. SET: Adjust date, time, and user selection.
Settings: User selection (User 1/User 2), Date/Time setup, Memory review with average calculation.
Proper technique ensures accurate readings.
Tip: Take measurements at the same time each day for consistent tracking.
Stores up to 200 total readings (100 per user).
Note: Memory is retained when batteries are replaced if done within 3 minutes.
Irregular Heartbeat Detection: Displays symbol if irregular rhythm detected during measurement. Hypertension Indicator: Shows symbol if systolic ≥135 mmHg or diastolic ≥85 mmHg. Body Movement Detection: Alerts if excessive movement occurs; may require restart.
Remove batteries if not using for extended period. Clean with soft, dry cloth; do not use solvents or abrasives. Store in cool, dry place.
CAUTION! Do not immerse in water; avoid extreme temperatures and humidity.
FDA Cleared: K number [Insert K number if applicable]. CE Marked: Meets European Medical Device Directive requirements. Manufacturer: Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries. |
| Error E1 displayed | Cuff not attached properly | Check cuff connection; reattach securely. |
| Error E2 displayed | Cuff over-inflated | Remove cuff; restart measurement. |
| Inconsistent readings | Improper positioning | Ensure cuff at heart level; sit still during measurement. |
| Memory not saving | Memory full | Clear memory for current user. |
| Irregular heartbeat symbol | Possible arrhythmia | Consult physician if symbol appears frequently. |
Reset: Remove batteries for 3 minutes to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com