The Omron M2 Blood Pressure Monitor is an automatic, upper-arm blood pressure monitoring device designed for home use. It features IntelliSense technology for comfortable inflation, a large LCD display with backlight, hypertension indicator, irregular heartbeat detector, memory storage for multiple users, and body movement detection. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with D-ring, Air tube, AC adapter port, Battery compartment, START/STOP button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for comfortable measurement |
| Large LCD Display with Backlight | Easy-to-read results in various lighting conditions |
| Hypertension Indicator | High blood pressure warning symbol |
| Irregular Heartbeat Detector | Detects possible arrhythmia during measurement |
| Memory Storage | Stores up to 30 readings for each of 2 users |
| Body Movement Detection | Alerts if movement is detected during measurement |
| START/STOP Button | Initiates and stops measurement |
| MEMORY Button | Recalls stored measurements |
| AC Adapter Port | For powering via AC adapter (optional) |
| Battery Compartment | Holds 4 AA batteries |
Read all instructions before use. Consult your physician for proper monitoring.
WARNING! This device is for home monitoring only, not for medical diagnosis. Always follow your doctor's instructions.
Front Panel: LCD display, START/STOP button, MEMORY button. Side: AC adapter port. Rear: Battery compartment.
Cuff Components: Arm cuff with D-ring closure, Air tube connector, Cuff wrap guide markers.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, User indicator, Memory index, Battery level, Error codes.
Prepare device for first use.
CAUTION! Use only recommended batteries or AC adapter. Do not mix old and new batteries.
For accurate results, follow these steps carefully.
Tip: Take measurements at the same time each day for consistent tracking.
Refer to the following classification (based on WHO guidelines):
| Category | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Optimal | < 120 | < 80 |
| Normal | 120-129 | 80-84 |
| High Normal | 130-139 | 85-89 |
| Grade 1 Hypertension | 140-159 | 90-99 |
| Grade 2 Hypertension | 160-179 | 100-109 |
| Grade 3 Hypertension | ≥ 180 | ≥ 110 |
Symbols: Hypertension indicator appears if systolic ≥ 135 or diastolic ≥ 85. Irregular heartbeat symbol appears if detected. Body movement symbol appears if excessive movement occurs.
Stores up to 30 readings for each of 2 users.
Note: Memory is retained when batteries are removed if done within 3 minutes.
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Never immerse device in water. Do not autoclave or sterilize.
Warning: Remove batteries if device will not be used for extended period.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all batteries; check polarity. |
| Error E1 | Cuff not attached properly | Ensure air tube is fully connected. |
| Error E2 | Cuff over-inflated | Deflate completely and restart. |
| Error E3 | Measurement error | Reposition cuff at heart level; remain still. |
| Inconsistent readings | Incorrect cuff position | Ensure cuff is 1-2 cm above elbow on bare skin. |
| Irregular heartbeat symbol | Possible arrhythmia | Consult physician if symbol appears frequently. |
| Memory not storing | Memory full | Clear memory or overwrite old readings. |
Reset: Remove batteries for 3 minutes to reset device.
Service: Contact authorized Omron service center. Do not attempt to repair yourself.