The Omron HEM RML31 is an automatic upper arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate and comfortable measurement, hypertension indicator, irregular heartbeat detection, body movement detection, memory storage for multiple users, and a large LCD display with backlight. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, Arm cuff, AC adapter, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays symbol for irregular heartbeats during measurement |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| Dual User Memory | Stores up to 60 readings per user (120 total) |
| Large LCD with Backlight | Easy-to-read display for day or night use |
| Date & Time Stamp | Records measurement date and time for tracking |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be powered by AC adapter (included) or 4 AA batteries |
| Cuff Wrap Guide | Ensures proper cuff placement for accurate readings |
Unpack and verify all items are present.
WARNING! Do not use if any components are damaged. Contact customer service for replacement parts.
Prepare the monitor for first use.
CAUTION! Do not use on injured or sore arm. Ensure cuff is not too tight or loose.
Front Panel: START/STOP button, SET button, MEMORY button. Display Icons: Systolic/Diastolic values, Pulse rate, User indicator (1/2), Date/Time, Battery indicator, Hypertension indicator, Irregular heartbeat symbol, Body movement symbol, Memory recall indicator.
Button Functions: START/STOP: Begin/stop measurement. SET: Set date/time and user selection. MEMORY: Recall stored measurements.
Display Layout: Large digits for systolic/diastolic pressure and pulse rate. Smaller icons for status indicators. Backlight activates during measurement and button presses.
Follow these steps for accurate readings.
Tip: Take measurements at the same time each day for consistent tracking.
Stores and recalls measurements for two users.
Note: Memory is maintained when batteries are replaced if done within 3 minutes.
Understanding display symbols.
| Symbol | Meaning | Action |
|---|---|---|
| ❤️ (flashing) | Irregular heartbeat detected | Consult physician if frequent |
| ↑↓ (arrow) | Body movement detected | Remain still and retake measurement |
| ⚠️ in circle | Hypertension indicator | Reading exceeds normal range |
| U1/U2 | User 1 or User 2 selected | Indicates whose memory is active |
| Battery icon | Low battery | Replace batteries soon |
| M with number | Memory recall mode | Displaying stored reading number |
Proper care ensures accurate measurements and long device life.
CAUTION! Do not immerse in water. Do not use alcohol or solvents. Do not disassemble.
FDA Cleared: For over-the-counter home use. CE Marked: Meets European medical device requirements. Manufactured by: Omron Healthcare Co., Ltd., Japan. Distributed by: Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
Compliance: Meets ANSI/AAMI/ISO 81060-2:2013 standards for electronic or automated sphygmomanometers.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace with new AA batteries |
| Error E1 displayed | Cuff not attached properly | Check cuff connection and retry |
| Error E2 displayed | Cuff pressure error | Remove and reapply cuff, ensure proper fit |
| Error E3 displayed | Measurement error | Remain still and retake measurement |
| Inconsistent readings | Improper posture or cuff placement | Sit correctly with cuff at heart level |
| Memory not saving | Memory full | Clear memory or switch to other user |
| Cuff doesn't inflate | Blocked air tube or leak | Check tube connections, ensure no kinks |
| Backlight not working | Battery saving mode | Backlight activates during use only |
Reset: Remove batteries for 3 minutes to reset unit.
Service: 1-800-634-4350; www.omronhealthcare.com