The Omron HEM RML31 is an automatic blood pressure monitor with IntelliSense technology for accurate and comfortable readings. It features a large, easy-to-read display, memory storage for multiple users, irregular heartbeat detection, and a body movement indicator. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff, AC adapter port, Battery compartment, START/STOP button, Memory button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Large LCD Display | Shows systolic/diastolic pressure, pulse, and indicators clearly |
| Memory Storage | Stores up to 60 readings with date and time stamp |
| Irregular Heartbeat Detector | Detects and displays an icon for irregular heartbeats during measurement |
| Body Movement Indicator | Alerts user if movement is detected during measurement |
| Multi-User Mode | Supports memory for two separate users |
| Cuff Wrapping Guide | Ensures proper cuff application for accurate results |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes of inactivity |
| AC Adapter Compatible | Can be powered by included AC adapter (optional) |
| Validated Accuracy | Clinically validated for accuracy and reliability |
Read all instructions before use. For personal home use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your doctor about your blood pressure.
Familiarize yourself with the main components.
CAUTION! Do not bend or twist the air tube excessively.
Prepare the monitor for first use.
Tip: For the most accurate readings, rest for 5 minutes before measuring.
Follow these steps for a proper reading.
WARNING! Do not move your arm or talk during measurement.
The monitor stores readings for two users (User 1 and User 2).
Note: Memory is maintained when batteries are removed.
Icons and symbols on the LCD screen.
| Symbol | Meaning |
|---|---|
| 120 / 80 | Systolic / Diastolic pressure (mmHg) |
| Pulse 72 | Pulse rate (beats per minute) |
| User 1 / User 2 | Indicates which user's memory is active |
| Irregular Heartbeat Icon | Appears if an irregular rhythm is detected |
| Body Movement Icon | Appears if excessive movement is detected |
| Clock Icon | Indicates memory contains date/time data |
| Battery Icon | Indicates battery level (replace when low) |
| AVG | Displayed when showing average readings |
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not disassemble or attempt to repair the unit.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Dead batteries, improper connection | Replace all 4 batteries. Ensure AC adapter is firmly connected. |
| Error Code "E" appears | Cuff not wrapped correctly, movement | Re-wrap cuff properly. Remain still and retry. |
| Irregular Heartbeat Icon flashes | Irregular rhythm detected | Take another measurement. If icon appears frequently, consult your doctor. |
| Inaccurate reading | Improper posture, talking, recent activity | Rest for 5 minutes. Sit correctly with cuff at heart level. Do not talk. |
| Cuff does not inflate | Air tube leak, blocked tube, weak batteries | Check tube connections. Replace batteries. Ensure cuff is not twisted. |
| Memory not displayed | Memory cleared or no readings stored | Ensure you are viewing the correct user memory. Take a new reading to store. |
Reset: Remove batteries and AC adapter for 1 minute, then reinstall.
Omron Healthcare, Inc. warrants this unit to be free from defects in materials and workmanship for a period of Five (5) Years from the date of purchase. This warranty covers repair or replacement of the unit at Omron's discretion.
For Service or Questions:
Omron Healthcare, Inc.
Customer Support: 1-800-634-4350
Website: www.omronhealthcare.com
Note: This warranty does not cover damage from accident, misuse, or unauthorized repair.