The Omron HEM-773 is an upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a wide-range D-ring cuff (22-42 cm), irregular heartbeat detection, hypertension indicator, 200-memory storage with date/time stamp, body movement detection, and averaging of last three readings. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, D-ring cuff, AC adapter, instruction manual, storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| D-Ring Cuff (22-42 cm) | Easy-to-wrap wide-range cuff for proper fit |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Displays warning symbol if reading exceeds hypertension threshold |
| 200-Memory Storage | Stores up to 200 readings with date and time stamp |
| Body Movement Detection | Alerts if excessive movement affects measurement accuracy |
| Average of Last 3 Readings | Calculates average of last three measurements taken within 10 minutes |
| Clock Function | Built-in clock for time/date stamp on stored readings |
| Automatic Power Off | Conserves battery by turning off after 2 minutes of inactivity |
| Dual Power Source | Operates on 4 AA batteries or AC adapter (included) |
Read all instructions before use. For accurate measurements and safety:
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of readings.
Prepare device for first use:
CAUTION! Ensure cuff is not too tight or loose. Air tube should run down center of arm.
Front Panel: START/STOP button, MEMORY button, CLOCK button, UP/DOWN buttons, LCD display.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Hypertension indicator, Body movement detection, Memory number, Date/Time, Battery indicator, Average value symbol.
Cuff: D-ring mechanism, air tube connector, index line for proper fit.
Follow these steps for accurate readings:
Tip: Take measurements at same time each day for consistent tracking.
Device stores up to 200 readings with date/time:
Note: Memory is retained even when batteries are removed.
Irregular Heartbeat Detection: Symbol appears if irregular rhythm detected during measurement. Hypertension Indicator: Warning symbol displays if systolic ≥135 mmHg or diastolic ≥85 mmHg. Body Movement Detection: Symbol appears if excessive movement affects accuracy.
Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.
CAUTION! Do not immerse in water or use near flammable gases.
FDA Cleared: K013385. CE Marked: Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd., Japan. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new alkaline batteries. |
| Error E1 displayed | Cuff not wrapped properly | Rewrap cuff ensuring index line within range. |
| Error E2 displayed | Excessive movement during measurement | Remain still and retake measurement. |
| Error E3 displayed | Pulse too weak or irregular | Rest 30 minutes and retry. Consult physician if persistent. |
| Inconsistent readings | Incorrect posture or timing | Ensure proper posture and rest 5 minutes before measurement. |
| Cuff doesn't inflate | Air leak or blockage | Check cuff and tube for damage. Ensure secure connection. |
| Memory not working | Memory full or corrupted | Clear memory and retry. Reset device if needed. |
Reset: Remove batteries, wait 1 minute, reinsert batteries.
Service: 1-800-634-4350; www.omronhealthcare.com