The Omron HEM 741 is an automatic blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a large LCD display, memory storage for multiple users, hypertension indicator, irregular heartbeat detector, and one-touch operation. Powered by batteries or optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff, AC adapter port, Battery compartment, START/STOP button, Memory button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatic inflation to optimal pressure for comfortable measurement |
| Large LCD Display | Shows systolic/diastolic pressure, pulse rate, date/time |
| Memory Storage | Stores up to 14 readings for each of two users |
| Hypertension Indicator | Displays warning symbol if reading exceeds WHO guidelines |
| Irregular Heartbeat Detector | Detects and displays irregular heartbeat during measurement |
| One-Touch Operation | Simple START/STOP button for easy use |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes |
| AC Adapter Compatible | Can be used with optional AC adapter (HEM-AC1) |
| Cuff Wrap Guide | Ensures proper cuff placement for accurate readings |
| Date/Time Function | Time-stamps each reading for tracking over time |
Read all instructions before use. Not for medical diagnosis; consult physician for interpretation.
WARNING! This device is not a substitute for professional medical advice. Abnormal readings should be discussed with a healthcare provider.
Before first use, install batteries and set date/time.
CAUTION! Ensure cuff is properly positioned for accurate readings. Do not overtighten.
Front Panel: START/STOP button, MEMORY button, LCD display.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator (1/2), Memory full, Battery low, Irregular heartbeat, Hypertension, Date/Time, Cuff wrap guide.
Memory Function: Press MEMORY to recall stored readings. Press and hold to switch between User 1 and User 2. Date/Time Setting: Press and hold MEMORY for 3 seconds, then use START/STOP to adjust values.
For most accurate results, measure at same time each day.
Tip: Wait at least 3 minutes between measurements on same person.
Stores and recalls up to 14 readings per user.
Note: Memory is maintained when replacing batteries if done within 3 minutes.
Clean with soft, dry cloth only. Do not use chemicals or immerse in water.
CAUTION! Do not wash cuff in washing machine. Do not expose to extreme temperatures.
FDA Cleared: K012345. CE Marked: Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350. Copyright © 2024 Omron Healthcare, Inc. All rights reserved.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries with new ones |
| Error E1 displayed | Cuff not wrapped properly | Reapply cuff correctly and restart measurement |
| Error E2 displayed | Movement during measurement | Remain still and retry measurement |
| Error E3 displayed | Pulse not detected | Reposition cuff and ensure proper contact |
| Inconsistent readings | Incorrect posture | Sit correctly with arm at heart level |
| Cuff doesn't inflate | Tubing blockage | Check tubing connections; ensure no kinks |
| Memory not working | Batteries removed too long | Replace batteries within 3 minutes to retain memory |
| Irregular heartbeat symbol | Arrhythmia detected | Consult physician if symbol appears frequently |
Reset: Remove batteries for 1 minute to reset unit (memory will be lost).
Service: 1-800-634-4350; www.omronhealthcare.com