The Omron HEM 7200 is an automatic blood pressure monitor designed for upper arm measurement. It features IntelliSense technology for comfortable inflation, a large display with backlight, irregular heartbeat detection, hypertension indicator, memory storage for multiple users, and body movement detection. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, Arm cuff, AC adapter, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for comfortable measurement |
| Large LCD Display | Clear backlit screen for easy reading |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol |
| Hypertension Indicator | High blood pressure warning symbol |
| Memory Function | Stores up to 60 readings for two users (120 total) |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Automatic Power Off | Conserves battery life |
| Date & Time Stamp | Records measurement date and time |
| Cuff Wrap Guide | Ensures proper cuff application |
| WHO Indicator | Classifies blood pressure according to WHO guidelines |
Read all instructions before use.
WARNING! This device is not a treatment device. Do not over-inflate cuff. Do not disassemble or modify the unit.
Front Panel: START/STOP button, MEMORY button, USER button, Display screen. Cuff: Arm tube, Air plug, Cuff wrap guide, Velcro fastener.
Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Hypertension indicator, User indicator, Memory indicator, Date/Time, Battery indicator, Error symbols.
CAUTION! Ensure cuff is correctly positioned and secured before measurement.
Insert batteries or connect AC adapter.
Tip: Remain still and quiet during setup and measurement.
Ensure proper cuff application and body position.
WARNING! Do not move or talk during measurement. Do not inflate cuff when not wrapped on arm.
Systolic Pressure: Top number (higher). Diastolic Pressure: Bottom number (lower). Pulse Rate: Beats per minute.
Symbols: Irregular heartbeat symbol (flashes if detected), Hypertension indicator (if systolic ≥135 or diastolic ≥85), User indicator (U1 or U2), Memory indicator (M), Date/Time, Battery indicator (low/replace), Error codes (E1-E5).
Note: Multiple irregular heartbeat detections may indicate arrhythmia; consult physician.
Stores 60 readings per user (120 total).
Tip: Use memory function to track blood pressure trends over time.
Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.
CAUTION! Do not disassemble or attempt repairs. Contact authorized service center.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all batteries with new ones. |
| Error E1 appears | Cuff not wrapped properly | Re-wrap cuff correctly and restart measurement. |
| Error E2 appears | Measurement error | Remain still and retry. Check cuff connection. |
| Error E3 appears | Pulse too irregular | Wait and retry. Consult physician if frequent. |
| Inaccurate reading | Wrong position/movement | Ensure proper cuff position and remain still. |
| Memory not working | Memory full/batteries low | Clear memory or replace batteries. |
| Cuff does not inflate | Air leak/tube blockage | Check cuff and tube for damage. Ensure proper connection. |
Reset: Remove batteries for 1 minute to reset unit.
Service: Contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com