Omron HEM 7122 Manual

The Omron HEM 7122 is an automatic upper arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate and comfortable measurement, a large LCD display with backlight, hypertension indicator, irregular heartbeat detection, memory storage for up to 30 readings, and one-touch operation. Powered by 4 AA batteries or AC adapter (optional). Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Parts Identification 4. Specifications 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. Care & Maintenance 9. Error Messages 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Arm cuff with D-ring, AC adapter port (optional), START/STOP button, Memory button.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for comfortable measurement
Large LCD DisplayEasy-to-read backlit screen showing systolic/diastolic pressure and pulse
Hypertension IndicatorDisplays warning symbol if reading exceeds WHO guidelines
Irregular Heartbeat DetectionDetects and displays symbol for irregular pulse during measurement
Memory FunctionStores up to 30 readings with date and time stamp
One-Touch OperationSimple START/STOP button for easy use
Cuff Wrapping GuideVisual indicator for proper cuff placement
Automatic Power OffConserves battery life by turning off after 1 minute of inactivity
AC Adapter CompatibleOptional AC adapter for continuous use (model EA-ADP10)
World Health Organization (WHO)Classification indicator for blood pressure ranges

Safety Precautions

Read all instructions before use. For personal home use only.

  1. Do not use on infants, children, or persons unable to express themselves.
  2. Do not use during physical exercise or immediately after.
  3. Consult physician for proper cuff size if arm circumference is outside 22-32 cm range.
  4. Do not use on injured or sore arm.
  5. Keep device away from electromagnetic fields (microwaves, mobile phones).

WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of readings.

Parts Identification

Front View: LCD display, START/STOP button, Memory button. Side: AC adapter port. Bottom: Battery compartment. Cuff: Arm tube, D-ring, air plug, artery mark.

  1. LCD Display: Shows systolic/diastolic pressure, pulse, date/time, memory index, indicators.
  2. START/STOP Button: Starts and stops measurement.
  3. Memory Button: Recalls stored measurements.
  4. AC Adapter Port: For optional external power.
  5. Battery Compartment: Holds 4 AA batteries.
  6. Cuff: Includes artery mark for proper positioning.

CAUTION! Do not disassemble the device. Refer servicing to qualified personnel.

Specifications

Initial Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Set date and time: Press and hold Memory button for 3 seconds, use START/STOP to adjust.
  3. Connect cuff: Insert air plug into main unit until it clicks.
  4. Test device: Without wearing cuff, press START/STOP to verify display lights up.

Tip: Use fresh alkaline batteries for best performance. Remove batteries if not using for extended period.

Taking a Measurement

For accurate results, follow these steps carefully.

  1. Rest for 5 minutes before measurement. Sit comfortably with feet flat on floor.
  2. Apply cuff: Place cuff on bare upper arm 1-2 cm above elbow. Artery mark should align with brachial artery.
  3. Secure cuff: Wrap snugly but not too tight. Allow room for one finger between cuff and arm.
  4. Position arm: Rest arm on table with cuff at heart level. Palm facing upward.
  5. Start measurement: Press START/STOP button. Cuff will inflate automatically.
  6. Remain still: Do not move or talk during measurement.
  7. Read results: Systolic/diastolic pressure and pulse display when measurement completes.
  8. Cuff deflation: Automatic. Remove cuff after measurement.

Important: Take measurements at same time each day for consistent tracking. Avoid caffeine, smoking, or alcohol 30 minutes before measurement.

Memory Function

Device stores last 30 readings with date and time.

  1. View memory: Press Memory button. Most recent reading displays with memory index (1-30).
  2. Scroll through memory: Press Memory button repeatedly to view previous readings.
  3. Clear memory: When memory is full, oldest reading is automatically overwritten.
  4. Average reading: Display shows average of last 3 readings taken within last 10 minutes.

Note: Memory is retained when batteries are removed (internal backup).

Care & Maintenance

Proper care ensures accurate measurements and long device life.

  1. Clean with soft, dry cloth only. Do not use chemicals or immerse in water.
  2. Store in cool, dry place away from direct sunlight and extreme temperatures.
  3. Remove batteries if not using for more than 3 months.
  4. Replace cuff if it becomes damaged or shows signs of wear.
  5. Do not bend or twist air tube excessively.

CAUTION! Never wash cuff or main unit. Do not disassemble any part of the device.

Error Messages

DisplayMeaningAction
E1Cuff not properly attached or air leakReconnect cuff securely; check for damage
E2Pressure error during measurementRemain still; retake measurement
E3Pulse signal too weak or irregularReposition cuff; ensure proper placement
E4Measurement result outside rangeRetake measurement; consult physician if persistent
E5Device malfunctionContact Omron customer service
LoLow batteryReplace all 4 batteries

Regulatory Information

FDA Cleared: K012456. CE Mark: Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd., Japan. Distributed by Omron Healthcare, Inc. For support in US/Canada: 1-800-634-4350. International: www.omronhealthcare.com. This device complies with Part 15 of FCC Rules. Copyright © Omron Healthcare. All rights reserved.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries with fresh alkaline batteries
Inaccurate readingImproper cuff placementEnsure cuff is at heart level; artery mark aligned properly
Error during measurementMovement or talkingRemain completely still and silent during measurement
Cuff doesn't inflateAir leak or blockageCheck cuff connection; ensure air tube not kinked
Memory not workingBatteries removed too longMemory may clear if batteries out for extended period
Backlight not workingPower saving modeBacklight activates during measurement only

Reset: Remove batteries for 5 minutes, then reinsert to reset device.

Service: 1-800-634-4350 (US/Canada); www.omronhealthcare.com