The Omron HEM 711 is an automatic upper arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate and comfortable measurement, a large LCD display with backlight, hypertension indicator, body movement detection, irregular heartbeat detection, memory storage for multiple users, and one-touch operation. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit, Arm cuff, AC adapter, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for accurate measurement |
| Large LCD Display | Easy-to-read backlit screen showing systolic/diastolic pressure and pulse |
| Hypertension Indicator | Displays warning symbol if reading exceeds WHO guidelines |
| Irregular Heartbeat Detection | Detects and displays symbol for irregular heartbeats during measurement |
| Body Movement Detection | Alerts user if movement is detected during measurement |
| Memory Function | Stores up to 14 readings for each of two users |
| One-Touch Operation | Simple START/STOP button for easy use |
| Cuff Wrapping Guide | Ensures proper cuff application for accurate results |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be powered by AC adapter (sold separately) or batteries |
Read all instructions before use to ensure safe and accurate operation.
WARNING! This device is for home monitoring only, not for medical diagnosis. Consult your physician for interpretation of readings.
Familiarize yourself with the main components of the device.
CAUTION! Ensure all parts are present and undamaged before first use.
Prepare the device for first-time use.
Tip: For most accurate results, use AC adapter (model EA-ADP01) to ensure consistent power.
Follow these steps for accurate blood pressure measurement.
WARNING! Do not inflate cuff when not wrapped around arm. Take measurements at same time each day for consistent tracking.
The LCD display provides comprehensive measurement information.
| Symbol | Meaning |
|---|---|
| SYS/ mmHg | Systolic blood pressure reading |
| DIA/ mmHg | Diastolic blood pressure reading |
| Pulse symbol | Pulse rate in beats per minute |
| Irregular Heartbeat symbol | Detected irregular heartbeat during measurement |
| Body Movement symbol | Movement detected - measurement may be inaccurate |
| Hypertension Indicator | Reading exceeds 135/85 mmHg (home monitoring guideline) |
| Memory symbol | Indicates stored reading is being displayed |
| User indicator | Shows USER 1 or USER 2 for memory recall |
| Battery indicator | Shows remaining battery power |
| Date/Time | Displayed during memory recall |
The device stores up to 14 readings for each of two users.
Note: When memory is full, oldest reading is automatically deleted to store new reading.
Proper care ensures accurate measurements and extends device life.
CAUTION! Do not wash cuff in washing machine or use bleach. Do not expose device to strong shocks or vibrations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new alkaline batteries |
| Error E1 displayed | Cuff not wrapped properly | Rewrap cuff correctly and restart measurement |
| Error E2 displayed | Movement during measurement | Keep still and restart measurement |
| Error E3 displayed | Pulse too weak or irregular | Rest 5 minutes and try again. Consult physician if persistent |
| Error E4 displayed | Pressure over 300 mmHg | Device may be defective. Contact service center |
| Inconsistent readings | Incorrect posture or cuff position | Follow measurement procedure exactly. Take 2-3 readings 1 minute apart |
| Cuff doesn't inflate | Air leak or hose not connected | Check hose connection. Ensure cuff is not torn or damaged |
| Memory not working | Batteries removed too long | Memory clears if batteries removed over 1 minute. Reset date/time |
Reset: Remove batteries for 1 minute to reset device to factory settings.
Service: For technical support, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com