The Omron HEM 637 is an automatic blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a large LCD display, memory storage for multiple users, irregular heartbeat detection, hypertension indicator, and one-touch operation. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit, Arm cuff, AC adapter, Instruction manual, Storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Large LCD Display | Easy-to-read results for systolic, diastolic, pulse, and date/time |
| Memory Storage | Stores up to 60 readings for two users (30 each) |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol during measurement |
| Hypertension Indicator | High blood pressure warning based on WHO classification |
| One-Touch Operation | Simple START/STOP button for easy use |
| Automatic Power Off | Conserves battery life by turning off after 2 minutes of inactivity |
| Cuff Wrap Guide | Ensures proper cuff application for accurate readings |
| Date/Time Stamp | Records measurement time for tracking purposes |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
Read all instructions before use. For accurate measurements and safe operation.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of results.
Front Panel: LCD Display, START/STOP Button, MEMORY Button, USER Button, SET Button.
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, Irregular Heartbeat, Hypertension Indicator, Memory Number, User Indicator, Date/Time, Battery Level, Cuff Wrap Indicator.
Side/Rear: AC Adapter Jack, Battery Compartment, Air Tube Connection Port.
Prepare device for first use.
CAUTION! Use only recommended batteries. Remove batteries if device will not be used for extended period.
For accurate readings, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
Store and recall previous measurements.
Note: Memory is maintained when batteries are replaced if done within 3 minutes.
Interpretation of displayed information.
| Symbol | Meaning | Action |
|---|---|---|
| Systolic/Diastolic | Blood pressure reading (e.g., 120/80) | Compare to normal ranges |
| Pulse | Heart rate in beats per minute | Normal range: 60-100 bpm |
| Irregular Heartbeat | Possible arrhythmia detected | Consult physician if frequent |
| Hypertension Indicator | Reading exceeds 135/85 mmHg | Monitor and consult physician |
| Error Codes | E1-E5 displayed | Refer to troubleshooting section |
WARNING! This device is for home monitoring only. Do not self-diagnose or self-treat based on readings.
Proper care ensures accurate measurements and long device life.
CAUTION! Do not immerse in water. Do not use near flammable gases.
FDA Cleared: K number [Insert K number here]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © [Year] Omron Healthcare. All rights reserved. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries |
| Error E1 | Cuff not wrapped properly | Rewrap cuff and retry measurement |
| Error E2 | Excessive movement during measurement | Remain still and retry |
| Error E3 | Pulse too irregular to measure | Wait 5 minutes and retry |
| Error E4 | Cuff pressure too high | Check cuff connection and retry |
| Error E5 | Device malfunction | Contact service center |
| Inaccurate readings | Improper posture or cuff position | Follow measurement instructions carefully |
| Memory not saved | Batteries removed too long | Replace batteries within 3 minutes |
Reset: Remove batteries for 3 minutes, then reinsert to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com