The Omron BP786 is an upper arm blood pressure monitor with IntelliWrap Cuff, TrueRead technology, and Bluetooth connectivity. It features a large backlit display, irregular heartbeat detection, hypertension detection, body movement detection, and stores up to 200 readings for two users. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main unit with display, IntelliWrap Cuff, AC adapter, storage case, instruction manual.
| Feature | Description |
|---|---|
| IntelliWrap Cuff | Pre-formed cuff for easy self-wrapping |
| TrueRead Technology | Provides accurate readings |
| Bluetooth Connectivity | Syncs data with Omron Connect app |
| Backlit Display | Easy-to-read screen in low light |
| Irregular Heartbeat Detection | Detects irregular heart rhythms during measurement |
| Hypertension Detection | Indicates if reading is in hypertension range |
| Body Movement Detection | Alerts if movement affects accuracy |
| Dual User Memory | Stores up to 200 readings for two users |
| Date and Time Stamp | Records measurement date and time |
| AC Adapter Port | For power connection |
Read all instructions before use.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your doctor for interpretation of readings.
Unpack and inspect contents. Insert batteries or connect AC adapter.
CAUTION! Use only specified AC adapter. Do not mix old and new batteries.
Front Panel: START/STOP button, SET button, Memory button, User button.
Display Icons: User indicator, Memory full, Bluetooth, Heartbeat, Movement, Hypertension, Battery low, Date/Time.
Settings: Date/Time, User selection, Memory review, Bluetooth pairing.
For accurate readings, sit quietly for 5 minutes before measuring.
Tip: Take measurements at same time each day for consistency.
Sync data to smartphone for tracking and sharing.
Note: App provides trends, averages, and export options.
Review stored readings on device or app.
CAUTION! Deleting memory cannot be undone.
Clean with soft, dry cloth. Do not immerse in water.
WARNING! Do not use alcohol or abrasive cleaners.
FDA Cleared: KXXXXXX. FCC Part 15: Class B digital device; complies with interference limits. CE Marked. Manufactured for Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries or connect AC adapter. |
| Error code E1 | Cuff not wrapped correctly | Rewrap cuff and restart measurement. |
| Error code E2 | Body movement during measurement | Remain still and retry. |
| Bluetooth not connecting | Bluetooth off or out of range | Enable Bluetooth on phone; move within 10 feet. |
| Inconsistent readings | Incorrect cuff position or talking/moving | Ensure cuff at heart level; sit quietly. |
| Cuff does not inflate | Cuff tube not connected | Check tube connection to main unit. |
Reset: Remove batteries for 1 minute to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com