The Omron BP760N is an automatic upper arm blood pressure monitor with IntelliSense technology, irregular heartbeat detection, hypertension indicator, 60 memory storage, one-touch operation, and body movement detection. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff, AC adapter (optional), Batteries, Storage case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Shows color-coded blood pressure levels |
| 60 Memory Storage | Stores measurements for two users (30 each) |
| Body Movement Detection | Alerts if movement is detected during measurement |
| One-Touch Operation | Simple START/STOP button |
| Cuff Wrap Guide | Ensures proper cuff application |
| Date & Time Display | Time-stamps all measurements |
| Automatic Power Off | Conserves battery life |
| AC Adapter Compatible | Optional AC adapter operation |
Unpack and verify all components are present.
WARNING! Do not use if any components are damaged or missing. Contact customer service immediately.
Front Panel: LCD Display, START/STOP Button, Memory Button, User Select Button (1/2).
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, Irregular Heartbeat Symbol, Hypertension Indicator (color bars), User Indicator, Memory Indicator, Date/Time, Low Battery Symbol, Error Codes.
Cuff Components: Air tube connector, Velcro closure, artery position marker, metal ring.
Prepare device for first use.
CAUTION! Do not use on injured arm or if you have circulatory problems. Consult physician first.
For accurate readings, follow these steps.
Tip: Take measurements at same time each day for consistent tracking.
Stores 60 measurements (30 per user).
Note: Date and time are stored with each measurement.
| Symbol | Meaning | Action |
|---|---|---|
| Normal Range | Systolic < 120, Diastolic < 80 | Green zone - Continue monitoring |
| Prehypertension | Systolic 120-139, Diastolic 80-89 | Yellow zone - Monitor regularly |
| Hypertension Stage 1 | Systolic 140-159, Diastolic 90-99 | Orange zone - Consult physician |
| Hypertension Stage 2 | Systolic ≥ 160, Diastolic ≥ 100 | Red zone - Seek medical attention |
| Irregular Heartbeat Symbol | Detected during measurement | Consult physician if frequent |
| Body Movement Symbol | Movement detected | Remain still and retake measurement |
WARNING! This device is for home monitoring only. Do not use for diagnosis or treatment decisions without consulting a healthcare professional.
Proper care ensures accurate measurements and device longevity.
CAUTION! Do not disassemble or attempt repairs. Contact authorized service center.
FDA Cleared: K number [Insert K number here]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © [Year] Omron Healthcare, Inc. All rights reserved. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries |
| Error Code E1 | Cuff not properly attached | Check cuff connection and retry |
| Error Code E2 | Measurement error | Remain still and retake measurement |
| Error Code E3 | Pulse too irregular | Wait 5 minutes and retry |
| Inaccurate readings | Improper cuff position | Reposition cuff at heart level |
| Memory not storing | Memory full | Clear memory for current user |
| Device won't turn off | Button stuck | Remove batteries and reinsert |
| Air leakage | Cuff damage | Replace cuff (part #HEM-CUFF-M) |
Reset: Remove batteries for 5 minutes, then reinsert.
Service: 1-800-634-4350; www.omronhealthcare.com