The Omron BP652 is a clinically validated, automatic upper arm blood pressure monitor with IntelliSense technology for comfortable inflation, irregular heartbeat detection, hypertension indicator, 2-user memory with 200 total readings, body movement detection, and a large backlit display. Powered by 4 AA batteries or AC adapter (optional). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with backlit LCD display, D-Ring Cuff (22-42 cm), AC adapter port, battery compartment, START/STOP button, MEMORY button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for comfortable measurement |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Displays symbol if systolic/diastolic readings are high |
| 2-User Memory | Stores up to 100 readings per user (200 total) |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Large Backlit Display | Easy-to-read results in various lighting conditions |
| D-Ring Cuff | Pre-formed cuff for easy self-application (22-42 cm) |
| Date & Time Stamp | Records measurement date and time for tracking |
| AVERAGE Mode | Displays average of last 3 readings taken within 10 minutes |
| AC Adapter Compatible | Optional AC adapter for continuous power |
This device is intended for non-invasive measurement of systolic and diastolic blood pressure and pulse rate from the upper arm of adult patients in home environments.
WARNING! This device is not a substitute for professional medical diagnosis. Always follow your physician's instructions regarding blood pressure monitoring.
Unpack and verify all components are present.
Note: Batteries and AC adapter are not included. Requires 4 AA batteries.
Front Panel: LCD Display, START/STOP Button. Side: AC Adapter Port. Bottom: Battery Compartment. Cuff: D-Ring, Air Tube, Metal Ring, Index Marker.
Display Symbols: User 1/2, Memory, Date/Time, Systolic, Diastolic, Pulse, Irregular Heartbeat, Hypertension, Body Movement, Low Battery, Average.
Buttons: START/STOP (start/stop measurement), MEMORY (recall memory, set user, date/time).
Before first use: Install batteries, set date/time, apply cuff properly.
CAUTION! Do not use rechargeable batteries. Ensure cuff is not twisted and fits snugly but not too tight.
For most accurate results, measure at the same time each day in a quiet environment.
Tip: Wait 2-3 minutes between measurements on the same person.
Normal range: Systolic <120 mmHg, Diastolic <80 mmHg (per American Heart Association).
| Symbol | Meaning | Action |
|---|---|---|
| Irregular Heartbeat | Detected irregular pulse rhythm | Consult physician if frequent |
| Hypertension Indicator | Systolic ≥135 or Diastolic ≥85 | Monitor regularly; consult physician |
| Body Movement | Movement detected during measurement | Repeat measurement while still |
| Average Symbol | Displaying average of last 3 readings | Use for tracking trends |
Note: Single readings may vary. Track trends over time rather than individual measurements.
2-user memory with 100 readings each. Press MEMORY button to recall stored readings.
Tip: Record readings in a log book along with notes about medication, activity, or symptoms.
Clean monitor with soft, dry cloth. Do not immerse in water or use chemicals.
CAUTION! Do not disassemble or attempt to repair. No user-serviceable parts inside.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries, improper installation | Replace batteries; ensure correct polarity |
| Error E1, E2, E3 | Cuff not properly attached, air leak | Reattach cuff securely; check for leaks |
| Error E5 | Body movement during measurement | Remain still and repeat measurement |
| Inconsistent readings | Improper cuff position, recent activity | Reposition cuff at heart level; rest 30 min |
| Cuff doesn't inflate | Blocked air tube, weak batteries | Straighten air tube; replace batteries |
| Memory not working | Batteries removed, memory full | Replace batteries within 5 minutes; old readings auto-delete when full |
Reset: Remove batteries for 5 minutes to reset microprocessor.
Service: For repairs, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com