The Omron BP 7450 is an upper arm blood pressure monitor with IntelliSense technology for accurate and comfortable readings. It features a large, easy-to-read display, memory storage for multiple users, irregular heartbeat detection, hypertension indicator, and body movement detection. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the optimal pressure for a comfortable reading |
| Dual User Memory | Stores up to 100 readings for each of two users |
| Irregular Heartbeat Detection | Detects and displays an icon for irregular heartbeats during measurement |
| Hypertension Indicator | Displays a warning symbol if your reading is above WHO guidelines |
| Body Movement Detection | Alerts you if movement is detected during measurement |
| Large LCD Display | Easy-to-read backlit screen with clear icons |
| Date & Time Stamp | Records the date and time with each reading |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be powered by AC adapter (included) or 4 AA batteries |
| Cuff Wrap Guide | Ensures proper cuff placement for accurate results |
Before using the device, read all safety instructions.
WARNING! This device is for home use only, not for professional medical use. Do not disassemble or modify the unit.
Familiarize yourself with the main components of the monitor.
CAUTION! Ensure the cuff is the correct size for your arm. Using an improperly sized cuff can lead to inaccurate readings.
Prepare the monitor for first-time use.
Tip: For consistent results, take measurements at the same time each day, before meals or medication.
Follow these steps for an accurate reading.
WARNING! Do not move or talk during the measurement, as this can affect accuracy.
Familiarize yourself with the symbols on the LCD screen.
| Symbol | Meaning |
|---|---|
| Heartbeat Icon (flashing) | Pulse rate is being measured/displayed |
| Irregular Heartbeat Icon | An irregular rhythm was detected during the measurement |
| Body Movement Icon | Excessive movement was detected; the reading may be inaccurate |
| Hypertension Indicator | Systolic reading is 135 mmHg or higher, or diastolic is 85 mmHg or higher (per WHO guidelines) |
| User 1 / User 2 Icon | Indicates which user profile is active |
| Battery Icon (low) | Indicates low battery power |
| Memory Icon | Indicates memory recall mode is active |
Unplug the AC adapter and remove batteries before cleaning.
CAUTION! Never attempt to repair the device yourself. Contact Omron customer service for support.
| Symptom / Error | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Dead batteries / No power | Insert new batteries or connect AC adapter. |
| Err CUF / Err 1 | Cuff not attached properly / Air leak | Check cuff connection. Ensure cuff is wrapped correctly and not too loose. |
| Err 2 / Pulse reading erratic | Body movement during measurement | Remain still and quiet. Retake measurement. |
| Err 3 | Pulse signal too weak or irregular | Ensure cuff is at heart level. Relax for 5 minutes and retry. |
| Inconsistent readings | Incorrect posture or cuff position | Sit correctly with arm supported at heart level. Re-wrap the cuff. |
| Memory not displaying | Wrong user selected / Memory cleared | Press MEMORY button to select correct user profile. |
Reset: Remove batteries for 1 minute to perform a soft reset.
Omron Healthcare, Inc. warrants this device to be free from defects in materials and workmanship for a period of Five (5) Years from the date of purchase when used in accordance with the instructions.
For service under warranty, contact Omron Customer Support. Have your model number (BP 7450) and proof of purchase ready.
Customer Support:
Phone: 1-800-634-4350
Website: www.omronhealthcare.com
Email: [email protected]
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.