The Omron BP 7350 is an upper arm blood pressure monitor with IntelliSense technology for accurate and comfortable readings. It features a wide-range D-Ring cuff (22-42 cm), irregular heartbeat detection, hypertension indicator, 60 memory storage with date and time stamp, body movement detection, and an easy-to-read backlit display. Below are key sections for safety, features, setup, operation, and maintenance.
Key components: Main unit with backlit display, D-Ring cuff, AC adapter, storage case, instruction manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| D-Ring Cuff | Pre-formed cuff (22-42 cm) for easy self-application |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| 60 Memory Storage | Stores readings with date and time for two users (30 each) |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Backlit Display | Easy-to-read LCD with illumination for low-light conditions |
| Date & Time Stamp | Automatic recording of measurement time |
| Average Reading | Calculates average of last three readings taken within 10 minutes |
| AC Adapter Option | Can be powered by AC adapter (included) or 4 AA batteries |
Read all instructions before use. For accurate measurements and safe operation.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician regarding your blood pressure.
Familiarize yourself with the device components.
CAUTION! Ensure all parts are clean, dry, and undamaged before use.
Prepare the device for first use.
Tip: For most accurate results, rest for 5 minutes before measuring and avoid talking or moving during measurement.
Follow these steps for accurate blood pressure measurement.
WARNING! Do not inflate cuff when not wrapped around arm. Do not use on injured or sore arm.
The LCD shows various icons and readings.
| Symbol | Meaning |
|---|---|
| SYS/ mmHg | Systolic blood pressure reading |
| DIA/ mmHg | Diastolic blood pressure reading |
| Pulse icon & value | Heart rate per minute |
| Irregular Heartbeat icon | Detected irregular heartbeat during measurement |
| Hypertension Indicator | Warning symbol for high blood pressure reading |
| Body Movement icon | Excessive movement detected |
| Memory icon (1 or 2) | User 1 or User 2 memory bank |
| Date & Time | Measurement timestamp |
| Average icon | Display of average reading |
| Low Battery icon | Replace batteries soon |
Stores up to 60 readings (30 per user).
Note: Memory is maintained when batteries are replaced if done within 3 minutes.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace with new AA batteries or use AC adapter. |
| Error E1 displayed | Cuff not properly attached | Check cuff connection; reattach air plug securely. |
| Error E2 displayed | Measurement error | Ensure cuff is properly positioned; remain still; retake measurement. |
| Error E3 displayed | Excessive movement | Keep arm still during measurement; retake reading. |
| Inconsistent readings | Incorrect cuff position | Reposition cuff at heart level; ensure proper fit (not too tight/loose). |
| Device won't turn on | Battery polarity incorrect | Check battery orientation; reinsert correctly. |
| Cuff doesn't inflate | Air leak in tube or cuff | Check for damage; ensure air plug is fully inserted. |
Reset: Remove batteries for 3 minutes to reset device to factory settings (memory will be cleared).
Proper care ensures accurate measurements and device longevity.
CAUTION! Never immerse device in water or other liquids. Do not use near oxygen tanks or flammable gases.
Omron Healthcare, Inc. provides limited warranty for this device. Refer to warranty card for details.
Customer Support: For questions or assistance:
Service Centers: Authorized service centers available nationwide. Check website for locations.
Regulatory: This device complies with Part 15 of FCC Rules. CE marked. Medical device classification according to applicable regulations.
Disposal: Dispose of device and batteries according to local regulations. Do not dispose with household waste.