Omron BP 5450 User Manual

The Omron BP 5450 is an upper arm blood pressure monitor featuring IntelliSense technology for accurate, comfortable readings, a large backlit display, irregular heartbeat detection, hypertension indicator, memory storage for multiple users, body movement detection, and one-touch operation. It is clinically validated and designed for home use. Below are key sections for safety, features, setup, operation, and maintenance.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Display 6. Taking Measurements 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with backlit LCD display, adjustable upper arm cuff, AC adapter, storage case, instruction manual, and quick start guide.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for comfortable measurement
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
Hypertension IndicatorDisplays warning symbol if reading exceeds WHO guidelines
Dual User MemoryStores up to 100 readings per user (200 total)
Body Movement DetectionAlerts if movement is detected during measurement
Large Backlit DisplayEasy-to-read results in various lighting conditions
One-Touch OperationSimple start/stop button for easy use
Cuff Wrap GuideVisual indicator for proper cuff placement
Date & Time StampRecords measurement date and time for tracking
Average ReadingCalculates average of last 3 readings taken within 10 minutes

Installation & Setup

Unpack and inspect all components. Ensure device is on stable surface.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter: Plug into DC jack on side of unit (optional for power).
  3. Prepare cuff: Unroll cuff and ensure air tube is not twisted.
  4. Set date and time: Press SET button, use arrows to adjust, press START/STOP to confirm.

WARNING! Use only specified batteries and adapter. Do not mix old and new batteries.

First-Time Use

Prepare for accurate measurement by following proper procedure.

  1. Rest quietly: Sit comfortably for 5 minutes before measuring.
  2. Apply cuff: Wrap cuff on bare upper arm 1-2 cm above elbow.
  3. Position arm: Rest arm on table with cuff at heart level.
  4. Take measurement: Press START/STOP button, remain still until complete.
  5. Record results: Note systolic/diastolic pressure and pulse rate.

CAUTION! Do not take measurements immediately after exercise, eating, or bathing.

Specifications

Controls and Display

Front Panel: START/STOP button, SET button, MEMORY button, UP/DOWN arrows.

Display Symbols: User indicator (1/2), Memory full, Irregular heartbeat, Hypertension, Body movement, Low battery, Average, Date/Time.

Settings Menu: Press SET to access date/time, user selection, memory review, unit reset. Memory Function: Press MEMORY to review stored readings by user and date.

Taking Measurements

For most accurate results, follow these steps carefully.

  1. Sit comfortably with feet flat on floor, back supported.
  2. Apply cuff to left arm (unless specified otherwise by physician).
  3. Ensure cuff is snug but not tight (should fit one finger underneath).
  4. Press START/STOP - device will inflate automatically.
  5. Remain still and quiet during measurement.
  6. Results display systolic, diastolic pressure, and pulse rate.
  7. Wait 2-3 minutes between measurements on same person.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Store and review up to 100 readings per user.

  1. Select user: Press SET, use arrows to choose User 1 or 2.
  2. Store reading: Measurements automatically save to selected user.
  3. Review memory: Press MEMORY button, use arrows to scroll.
  4. View average: Display shows average of last 3 readings.
  5. Clear memory: In SET menu, select "Clear All" (requires confirmation).

Note: Memory full indicator appears when 100 readings stored per user.

Understanding Results

Interpret your blood pressure readings using standard categories.

CategorySystolic (mmHg)Diastolic (mmHg)
NormalLess than 120and Less than 80
Elevated120-129and Less than 80
Hypertension Stage 1130-139or 80-89
Hypertension Stage 2140 or higheror 90 or higher
Hypertensive CrisisHigher than 180and/or Higher than 120

Warning Symbols: Hypertension indicator appears if reading exceeds 135/85 mmHg. Irregular heartbeat symbol appears if rhythm disturbance detected.

Care & Maintenance

Proper care ensures accurate measurements and long device life.

  1. Clean cuff: Wipe with soft, dry cloth. Do not wash or immerse in water.
  2. Clean unit: Use slightly damp cloth, then dry immediately.
  3. Store properly: Keep in storage case in cool, dry place.
  4. Replace batteries: When low battery symbol appears.
  5. Avoid: Extreme temperatures, humidity, direct sunlight, strong impacts.

CAUTION! Never use alcohol, benzene, or abrasive cleaners. Do not disassemble unit.

Regulatory Information

FDA Cleared: K number [insert if applicable]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured under ISO 13485 quality standards. Clinical validation: Protocol follows ANSI/AAMI/ISO 81060-2:2013. Copyright © Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 AA batteries
Error E1 displayedCuff not properly attachedCheck cuff connection, reattach securely
Error E2 displayedMeasurement errorRemain still, retake measurement
Error E3 displayedPulse too irregularWait, then retake measurement
Inconsistent readingsImproper cuff positionEnsure cuff at heart level, retighten
Memory not storingMemory fullClear memory or switch to other user
Cuff won't inflateAir leakCheck tube connections, replace cuff if damaged
Display dimLow batteryReplace batteries or use AC adapter

Reset: Remove batteries for 5 minutes, then reinsert to reset unit.

Service: 1-800-634-4350; www.omronhealthcare.com