Omron BP 5250 Manual

The Omron BP 5250 is an upper arm blood pressure monitor designed for home use, featuring IntelliSense technology for accurate and comfortable readings, a large backlit display, memory storage for multiple users, irregular heartbeat detection, hypertension indicator, and body movement detection. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Package Contents 3. Device Overview 4. Specifications 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit, Arm cuff, AC adapter, Instruction manual, Storage case.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for accurate reading
Large Backlit DisplayEasy-to-read results in various lighting conditions
Memory StorageStores up to 100 readings for two users (200 total)
Irregular Heartbeat DetectionDetects and displays irregular heartbeat symbol during measurement
Hypertension IndicatorDisplays color-coded indicator based on WHO classification
Body Movement DetectionAlerts user if movement is detected during measurement
Date & Time StampRecords date and time with each measurement
Average ReadingCalculates average of last three readings taken within 10 minutes
AC Adapter PortFor power connection (batteries also supported)
START/STOP ButtonInitiates and stops blood pressure measurement

Package Contents

Unpack and verify all components are present.

  1. Omron BP 5250 main unit
  2. Arm cuff (22-42 cm circumference)
  3. AC adapter (model EA-AC85)
  4. Instruction manual (this document)
  5. Storage case
  6. Quick start guide
  7. 4 x AA batteries (optional, not included in all regions)

WARNING! Do not use if any components are damaged. Contact customer service for replacement.

Device Overview

Familiarize yourself with the device controls and display symbols.

  1. Front: Large LCD display with backlight, START/STOP button.
  2. Top: Memory button, User selector button (1/2), Clock set button.
  3. Side: AC adapter port, Cuff connector port.
  4. Display Symbols: Systolic/Diastolic pressure, Pulse rate, Irregular heartbeat, User indicator, Memory indicator, Hypertension stage, Date/Time, Battery level.

CAUTION! Handle device with care; avoid dropping or exposing to extreme temperatures.

Specifications

Initial Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter: Plug into device and wall outlet (optional).
  3. Set date and time: Press and hold CLOCK button, use START/STOP to adjust values.
  4. Attach cuff: Connect cuff tube to device port until it clicks.
  5. Select user: Press USER button to select User 1 or User 2.

Tip: Use AC adapter for consistent power and to conserve batteries.

Taking a Measurement

For accurate readings, follow these steps carefully.

  1. Sit comfortably: Rest for 5 minutes before measuring.
  2. Apply cuff: Place cuff on bare upper arm 1-2 cm above elbow.
  3. Position arm: Rest arm on table with cuff at heart level.
  4. Start measurement: Press START/STOP button.
  5. Remain still: Do not talk or move during inflation and measurement.
  6. View results: Reading displays automatically when complete.
  7. Record measurement: Results are automatically stored in memory.
  8. Remove cuff: Wait for complete deflation before removing.

WARNING! Do not take measurements more than once every 3 minutes to allow circulation to return to normal.

Memory Function

Access and manage stored readings.

  1. View memory: Press MEMORY button to scroll through stored readings.
  2. Select user: Press USER button to switch between User 1 and User 2 memory.
  3. Average reading: Device automatically calculates average of last 3 readings.
  4. Clear memory: Press and hold MEMORY button for 3 seconds while in memory mode.

Note: Memory is maintained when batteries are removed (for approximately 3 minutes).

Understanding Results

Interpret your blood pressure readings correctly.

Blood Pressure CategorySystolic (mmHg)Diastolic (mmHg)Display Indicator
NormalLess than 120Less than 80Green zone
Elevated120-129Less than 80Yellow zone
Hypertension Stage 1130-13980-89Orange zone
Hypertension Stage 2140 or higher90 or higherRed zone
Hypertensive CrisisHigher than 180Higher than 120Red zone (flashing)

Irregular Heartbeat Symbol: Appears if irregular heartbeat is detected during measurement. Consult physician if this appears frequently.

Care & Maintenance

Proper care ensures accurate measurements and device longevity.

  1. Clean device: Use soft, dry cloth. Do not use alcohol, solvents, or water.
  2. Clean cuff: Wipe with damp cloth and mild detergent, then air dry completely.
  3. Store properly: Keep in storage case in cool, dry place away from direct sunlight.
  4. Replace batteries: When battery icon appears low, replace all 4 batteries.
  5. Cuff care: Do not fold or twist tubing; inspect regularly for wear.

CAUTION! Never immerse device in water or use abrasive cleaners.

Regulatory Information

FDA Cleared: K963675. CE Mark: Complies with European Medical Device Directive 93/42/EEC. Manufactured by Omron Healthcare Co., Ltd., Japan. Distributed by Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries or connect AC adapter
Error E1Cuff not attached properlyCheck cuff connection; reattach securely
Error E2Cuff pressure errorCheck cuff for leaks or damage; replace if necessary
Error E3Pulse detection errorEnsure proper cuff placement; remain still during measurement
Inconsistent readingsImproper positioningEnsure cuff at heart level; rest 5 minutes before measuring
Memory not workingBatteries removed too longMemory clears after 3 minutes without power; recharge promptly
Cuff won't inflateBlockage or damageCheck tubing for kinks; ensure proper connection

Reset: Remove batteries and AC adapter for 1 minute, then reinsert.

Service: 1-800-634-4350; www.omronhealthcare.com