The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm blood pressure monitoring device designed for home use. It features IntelliSense technology for accurate readings, hypertension detection, irregular heartbeat detection, body movement detection, and memory storage for multiple users. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Cuff with D-ring, AC adapter, Storage case, Instruction manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for accurate readings |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Dual User Memory | Stores up to 100 readings per user (200 total) |
| Date & Time Stamp | Records measurement date and time for tracking |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
| Cuff Wrap Guide | Indicates proper cuff placement |
| AC Adapter Port | For continuous power operation |
| START/STOP Button | Initiates and stops measurement |
Read all instructions before use. Consult physician for proper monitoring.
WARNING! This device is for home monitoring only, not for diagnosis. Always consult your physician about your readings.
Main Unit: LCD display, START/STOP button, MEMORY button, SET button, UP/DOWN buttons. Cuff: Arm cuff with D-ring closure, air tube, metal hook. Accessories: AC adapter, storage case, instruction manual.
LCD Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Irregular heartbeat symbol, Hypertension indicator, Body movement detection, User indicator (1/2), Memory full indicator, Low battery, Date/Time, Average reading.
Prepare device before first use.
CAUTION! Use only specified AC adapter. Do not mix old and new batteries.
For accurate readings, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
Blood Pressure Categories (American Heart Association):
| Category | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Normal | Less than 120 | and Less than 80 |
| Elevated | 120-129 | and Less than 80 |
| Hypertension Stage 1 | 130-139 | or 80-89 |
| Hypertension Stage 2 | 140 or higher | or 90 or higher |
| Hypertensive Crisis | Higher than 180 | and/or Higher than 120 |
Symbol Indicators: Hypertension symbol appears if systolic ≥135 or diastolic ≥85. Irregular heartbeat symbol appears if irregular rhythm detected during measurement. Body movement symbol appears if excessive movement detected.
View and manage stored readings.
Note: Memory full indicator appears when 100 readings stored for selected user.
Clean device regularly for optimal performance.
CAUTION! Do not immerse in water. Do not use alcohol, benzene, or thinner. Do not autoclave.
FDA Cleared: For over-the-counter home use. CE Marked: Complies with European Medical Device Directive. Manufactured by: Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350. This device complies with Part 15 of FCC Rules.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries |
| Error E1 | Cuff not properly attached | Reattach cuff securely |
| Error E2 | Excessive movement during measurement | Remain still and retake measurement |
| Error E3 | Pulse too irregular to measure | Wait 5 minutes and retry |
| Error E5 | Cuff pressure too high | Remove cuff and restart |
| Inconsistent readings | Improper cuff placement | Reposition cuff at heart level |
| Memory not storing | Memory full | Delete old readings or switch user |
| Cuff not inflating | Air leak or tube blockage | Check connections and tube |
Reset: Remove batteries for 1 minute to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com