The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm device designed for accurate at-home blood pressure and pulse rate measurement. It features IntelliSense technology for comfortable inflation, hypertension indication, irregular heartbeat detection, memory storage for multiple users, a large LCD display with backlight, body movement detection, and WHO classification indicator. Powered by batteries or optional AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter (optional), Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for comfortable measurement |
| Hypertension Indicator | Displays symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays symbol for pulse irregularities |
| Dual User Memory | Stores up to 100 readings per user (200 total) |
| WHO Classification Indicator | Color-coded bar graph shows blood pressure level |
| Body Movement Detection | Alerts if movement during measurement affects accuracy |
| Large LCD with Backlight | Easy-to-read display for day or night use |
| Date & Time Stamp | Records measurement date and time for tracking |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
| Automatic Power Off | Conserves battery life |
Read all instructions before use. Consult physician for interpretation of readings.
WARNING! This device is for home use only, not for professional medical diagnosis. Seek medical advice for health concerns.
Front Panel: START/STOP Button, Memory Button, User Button (1/2), Power Button. Display: Systolic/Diastolic readings, Pulse rate, WHO indicator, User icon, Memory icon, Date/Time, Battery indicator. Cuff: Arm tube, Metal ring, Air tube, Cloth hook.
Note: Ensure cuff size matches arm circumference (22-42 cm standard).
Before first use, install batteries and set date/time.
CAUTION! Use only recommended batteries. Remove batteries if not used for extended period.
Correct cuff placement is essential for accurate readings.
Tip: Always use same arm for consistent measurements.
Remain still and quiet during measurement.
WARNING! Do not inflate cuff when not wrapped around arm. Excessive pressure may cause injury.
Display icons and their meanings:
| Symbol | Meaning |
|---|---|
| Heart with '!' | Irregular heartbeat detected |
| Hand with waves | Body movement detected |
| User 1/2 | Current user selected |
| Clock | Date/Time display |
| Battery | Low battery indicator |
| Memory | Memory recall mode active |
| Bar graph (Green/Yellow/Red) | WHO blood pressure classification |
Note: If error symbols appear, refer to troubleshooting section.
View and manage stored readings.
CAUTION! Deleted readings cannot be recovered.
Unplug AC adapter (if used) and remove batteries before cleaning.
CAUTION! Never immerse unit in water. Do not autoclave.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries. |
| Error 'E' appears | Cuff not attached properly | Check cuff connection; reattach securely. |
| Irregular heartbeat symbol | Pulse irregularity detected | Consult physician if symbol appears frequently. |
| Body movement symbol | Movement during measurement | Remain still and retake measurement. |
| Inconsistent readings | Incorrect cuff position | Reapply cuff at heart level; wait 5 minutes between readings. |
| Cuff does not inflate | Air leak or blockage | Check tube connections; ensure cuff is not twisted. |
Reset: Remove batteries for 5 minutes, then reinstall.
Service: For repairs, contact authorized Omron service center. Do not attempt to disassemble unit.