Omron Blood Pressure Monitor Upper Arm Manual
The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm device for home use. It features IntelliSense technology for comfortable inflation, hypertension detection, irregular heartbeat detection, body movement detection, and a large, easy-to-read display. It stores readings for multiple users with date and time stamps. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Features at a Glance
Key components: Main Unit, Upper Arm Cuff, AC Adapter (if applicable), Instruction Manual, Storage Case.
| Feature | Description |
| IntelliSense Technology | Automatically inflates to the ideal level for each user |
| Hypertension Indicator | Displays symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detector | Detects pulse irregularities during measurement |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Dual User Memory | Stores up to 100 readings per user (200 total) |
| Date & Time Stamp | Records measurement date and time for tracking |
| Large Display | Easy-to-read backlit LCD screen |
| One-Touch Operation | Simple START/STOP button |
| Cuff Wrap Guide | Indicates correct cuff application |
| AC Adapter Compatible | Optional power source (batteries included) |
Safety Information
Read all instructions before use. For home use only.
- Do not use on infants, small children, or persons unable to express themselves.
- Do not use during blood dialysis or if you have pre-eclampsia (consult physician).
- Do not wrap cuff over clothing. Apply directly to bare upper arm.
- Remain still and do not talk during measurement.
- Wait at least 5 minutes between consecutive measurements on the same person.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your doctor for interpretation of readings and treatment decisions.
Parts Identification
Familiarize yourself with the device components.
- Main Unit: Contains display, control buttons, and air hose connector.
- Display: Shows systolic/diastolic pressure, pulse, indicators, and memory.
- START/STOP Button: Initiates and stops measurement.
- Memory Button: Recalls stored readings.
- Upper Arm Cuff: Wraps around upper arm. Contains air bladder and D-ring.
- Air Hose: Connects cuff to main unit.
- AC Adapter Jack: For optional external power (model dependent).
- Battery Compartment: Holds 4 AA batteries.
CAUTION! Do not bend or twist the air hose excessively.
Initial Setup & Battery Installation
Power on the device; set date and time.
- Install Batteries: Open battery compartment, insert 4 AA batteries observing polarity.
- Set Date/Time: Press and hold the MEMORY button for 3 seconds. Use START/STOP to adjust values, MEMORY to confirm and move to next setting.
- Connect AC Adapter (Optional): Plug adapter into jack and into wall outlet. Device will use AC power and conserve batteries.
Tip: Replace batteries when the low battery icon appears on the display.
Applying the Cuff
- Cuff Size: Fits arm circumferences 9" to 17" (22cm to 42cm). Use correct size for accurate readings.
- Position: Sit comfortably with feet flat on the floor. Rest arm on a table so the cuff is at heart level.
- Application:
- Insert arm through cuff loop. Place cuff 0.5-1 inch above elbow.
- Secure cuff snugly using the cloth D-ring. Hose should align with center of inner arm.
- Cuff should be tight enough to fit one fingertip under the top edge.
Taking a Measurement
Remain seated and relaxed for 5 minutes before measuring.
- Apply cuff correctly as described.
- Sit still with back straight, feet flat, and cuff at heart level.
- Press the START/STOP button. All display symbols will appear briefly.
- The cuff will inflate automatically. Remain perfectly still and quiet.
- Measurement completes when cuff deflates fully. Systolic, diastolic, and pulse readings display.
- Press START/STOP to turn the unit off, or it will power off automatically after 1 minute.
WARNING! Do not inflate the cuff when it is not wrapped around an arm.
Understanding the Display
Access OSD via TV MENU or SETUP (DVD). Front Panel: POWER, OPEN/CLOSE, AUTO/DPMS, MUTE.
Icons & Indicators:
| Symbol | Meaning |
| User 1 / User 2 | Indicates which user's memory is active |
| Heart Icon with '!' | Irregular Heartbeat detected |
| Movement Symbol | Excessive body movement detected |
| Hypertension Symbol | Systolic ≥ 135 mmHg or Diastolic ≥ 85 mmHg |
| Clock Icon | Date/Time stamp for reading |
| Low Battery | Replace batteries soon |
| Memory Number | Current reading's position in memory (e.g., 045) |
Memory Function
Stores readings for two users (100 readings each).
- Select User: Press the MEMORY button before measurement to toggle between User 1 and User 2 icon.
- Recall Memory: Press MEMORY after the unit is on (but not measuring) to scroll through stored readings for the selected user. Displays reading number, values, date, and time.
- Clear Memory: To clear all readings for the current user, press and hold the MEMORY button while in memory recall mode until 'CLr' appears.
Tip: Take measurements at the same time each day for accurate tracking.
Care & Maintenance
Remove batteries before extended storage. Clean with a soft, dry cloth only.
- Do not immerse unit or cuff in water. Do not use alcohol, benzene, or abrasive cleaners.
- Cuff can be wiped with a damp cloth and mild detergent. Air dry completely before storage.
- Store device and cuff in the provided case in a cool, dry place away from direct sunlight.
- Avoid extreme temperatures, humidity, dust, and strong magnetic fields.
CAUTION! Do not disassemble, repair, or modify the device. Contact Omron for service.
Specifications
- Measurement Method: Oscillometric
- Measurement Range: Pressure: 0-299 mmHg, Pulse: 40-180 beats/min
- Accuracy: Pressure: ±3 mmHg, Pulse: ±5% of reading
- Memory: 100 readings x 2 users
- Power Source: 4 AA batteries or AC adapter (6V DC, model specific)
- Automatic Shut-off: Approx. 1 minute after measurement
- Cuff Size: 9" - 17" (22 - 42 cm) arm circumference
- Operating Conditions: 50°F to 104°F (10°C to 40°C), 30% to 85% RH
- Weight: Approx. 13.8 oz (390 g) without batteries
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| No display | Dead batteries, improper installation | Install new batteries correctly. Check polarity. |
| Error Code 'E' | Cuff not wrapped correctly, movement | Re-wrap cuff snugly. Remain still and retry. |
| Error Code 'HE' | Irregular heartbeat detected | Reading may be inaccurate. Rest and retry. If persistent, consult physician. |
| Inconsistent readings | Body position, talking, recent activity | Rest 5 min before measuring. Sit correctly with cuff at heart level. Do not talk. |
| Cuff does not inflate | Air hose leak, blockage, weak batteries | Check hose connections. Replace batteries. |
| Memory not saving | Memory full, wrong user selected | Clear memory for current user. Check user icon before measuring. |
Reset: Remove batteries and AC adapter for 1 minute to perform a soft reset.
Service: For technical support, visit www.omronhealthcare.com or call 1-800-634-4350.