The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm device designed for accurate at-home blood pressure and pulse measurement. It features IntelliSense technology for comfortable inflation, hypertension detection indicators, a large LCD display with backlight, memory storage for multiple users, irregular heartbeat detection, body movement detection, and AC adapter compatibility. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Parts Identification 4. Initial Setup & Battery Installation 5. Applying the Cuff 6. Taking a Measurement 7. Understanding the Display 8. Memory Function 9. Care & Maintenance 10. Specifications 11. Troubleshooting

Features at a Glance

Key components: Main Unit, Arm Cuff, AC Adapter, Storage Case, Instruction Manual.

FeatureDescription
IntelliSense TechnologyAutomatically adjusts inflation for comfortable measurement
Hypertension IndicatorDisplays symbol if systolic/diastolic readings are high
Irregular Heartbeat DetectionDetects and displays symbol for pulse irregularities
Body Movement DetectionAlerts if movement during measurement affects accuracy
Dual User MemoryStores up to 100 readings per user (200 total)
Large LCD with BacklightEasy-to-read display for day or night use
Date & Time StampRecords measurement date and time for tracking
AVG (Average) FeatureCalculates average of last 3 readings taken within 10 minutes
AC Adapter PortFor powering device without batteries
START/STOP ButtonInitiates and stops measurement

Safety Precautions

Read all instructions before use. Consult your physician for interpretation of readings.

  1. Do not use on infants, small children, or persons who cannot express themselves.
  2. Do not use on an arm with an intravenous drip or surgical wound.
  3. Do not inflate cuff when not wrapped around arm.
  4. Use only specified AC adapter. Do not disassemble or modify the unit.
  5. Keep device away from extreme temperatures, humidity, dust, and direct sunlight.

WARNING! This device is not a substitute for professional medical diagnosis. If readings are consistently abnormal, consult your physician immediately.

Parts Identification

Front of Main Unit: LCD Display, START/STOP Button, Memory Button, User Button (1/2), Power Adapter Jack.

Cuff: Arm tube, Cloth wrap, Metal D-ring, Air plug, Range index line.

Display Symbols: Systolic/Diastolic/Pulse readings, User indicator, Memory full, Battery low, Hypertension indicator, Irregular heartbeat symbol, Body movement symbol, Date/Time, AVG indicator.

Initial Setup & Battery Installation

Power the monitor using batteries or AC adapter.

  1. Open battery compartment on back of unit.
  2. Insert 4 AA batteries (LR6) observing correct polarity (+/-).
  3. Close compartment. For AC power, plug adapter into unit and wall outlet.
  4. Set date and time: Press and hold Memory button for 3 seconds, use START/STOP to adjust, press Memory to confirm.

CAUTION! Use only recommended batteries. Remove batteries if device will not be used for 3 months or more to prevent leakage.

Applying the Cuff

Tip: For consistent results, take measurements at the same time each day, avoiding meals, caffeine, exercise, or smoking for 30 minutes prior.

Taking a Measurement

  1. Sit in a chair with feet flat on floor and back supported.
  2. Apply cuff correctly as described.
  3. Press the User button (1 or 2) to select your memory profile.
  4. Press START/STOP. Cuff will inflate automatically. Remain still and quiet.
  5. Measurement completes when cuff deflates fully. Readings display.
  6. To turn unit off, press START/STOP again, or it will power off automatically after 1 minute.

WARNING! Do not move or talk during measurement. Ensure cuff is at heart level for accurate results.

Understanding the Display

Systolic Pressure: Top number (e.g., 120). Diastolic Pressure: Bottom number (e.g., 80). Pulse Rate: Beats per minute.

Symbol Guide:
User 1/2: Indicates which user's memory is active.
Hypertension Indicator: Flashes if systolic ≥135 mmHg or diastolic ≥85 mmHg.
Irregular Heartbeat Symbol: Appears if an irregular rhythm is detected.
Body Movement Symbol: Appears if excessive movement occurred.
AVG: Shows when average of last 3 readings is displayed.
Memory Full: Appears when 100 readings for that user are stored.
Low Battery: Indicates batteries need replacement.

Memory Function

Stores up to 100 readings per user with date and time.

  1. View memory: Press Memory button. Use START/STOP to scroll through readings.
  2. View average: While in memory mode, press User button to display average of all stored readings for that user.
  3. Delete memory: Press and hold User button for 3 seconds while in memory mode. "CLR" appears. Press User again to confirm deletion for that user.

Note: Memory is retained even when batteries are removed.

Care & Maintenance

Unplug AC adapter and remove batteries before cleaning.

  1. Wipe main unit and cuff with a soft, dry cloth. Do not use solvents or abrasives.
  2. Do not immerse any part in water. Do not wash cuff in washing machine.
  3. Store in provided case in a cool, dry place. Avoid bending air tube sharply.
  4. Replace cuff if it becomes damaged or excessively worn.

CAUTION! Do not disassemble or attempt to repair the unit. Contact Omron for service.

Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteries, improper installationReplace batteries; ensure correct polarity; check AC adapter connection.
Error Code "E" appearsCuff not attached, air leakEnsure cuff plug is fully inserted; check cuff/tube for damage.
Inaccurate readingImproper cuff position, movementReapply cuff correctly; remain still and quiet; arm at heart level.
Irregular Heartbeat symbol flashesPulse irregularity detectedTake another measurement. If symbol appears frequently, consult your physician.
Memory full100 readings stored for userDelete old readings from memory to store new ones.
Cuff does not inflateBlocked air tube, low powerCheck for kinks in tube; replace batteries; ensure plug is secure.

Reset: Remove batteries and AC adapter for 1 minute, then reinstall.

Service: For technical support or service, visit www.omronhealthcare.com or call 1-800-634-4350.