Omron Blood Pressure Monitor Manual Symbols

The Omron Blood Pressure Monitor features various symbols and indicators on its display and in its manual to guide users through proper operation, measurement results, and device status. Understanding these symbols is crucial for accurate blood pressure monitoring and interpreting readings correctly. Below are key sections explaining common symbols, their meanings, setup guidance, and troubleshooting based on display icons.

1. Common Display Symbols 2. Symbol Meanings & Functions 3. Initial Setup & Calibration 4. Measurement Indicators 5. Error & Alert Symbols 6. Battery & Power Indicators 7. Memory & Data Symbols 8. Proper Cuff Placement 9. Care & Maintenance 10. Safety Symbols 11. Troubleshooting Symbols

Common Display Symbols

Key symbols displayed on the monitor screen: Heartbeat/Pulse symbol, Systolic/Diastolic values, Battery indicator, Memory recall icon, Error/Alert symbols, Cuff fit indicator, Movement detection icon.

SymbolDescription
Heartbeat/Pulse iconIndicates pulse rate measurement in progress or displayed
Battery icon (empty/full)Shows remaining battery power level
Memory book/stack iconIndicates memory storage or recall mode
Exclamation mark inside triangleGeneral warning or error alert
Cuff with arrowIndicates improper cuff placement or inflation issue
Person moving iconDetects excessive movement during measurement
Clock symbolTime/date display or timer function
Bluetooth/Wireless iconIndicates wireless connectivity (on certain models)
Arrow up/downNavigation or value adjustment buttons
Power button symbolDevice on/off control

Symbol Meanings & Functions

Each symbol corresponds to a specific function or status.

  1. Heartbeat icon: Flashes during measurement; steady when pulse rate is displayed.
  2. Battery: Full icon = good power; empty/blinking = replace batteries.
  3. Memory: Number may appear showing stored readings; M1, M2 for multiple users.
  4. Error symbols: E1, E2, etc., with specific error codes in manual.
  5. Cuff indicator: Blinks if cuff is too loose, not attached, or leaking.

IMPORTANT! Refer to the specific model manual for exact symbol interpretations as they may vary.

Initial Setup & Calibration

Power on monitor; follow initial setup prompts if available.

  1. Set time/date: Use SET button and arrows to adjust clock symbol settings.
  2. User selection: Assign memory slots (User 1, User 2 icons) for multiple users.
  3. Cuff connection: Ensure cuff plug icon is not flashing, indicating secure connection.
  4. Test measurement: Take first reading to ensure all symbols display correctly.

NOTE: Some models require initial calibration; follow on-screen symbols.

Measurement Indicators

Error & Alert Symbols

Common error codes and their meanings.

E1: Cuff not properly attached or leaking. E2: Pressure error during measurement. E3: Pulse signal too weak or irregular. E4: Excessive movement detected. E5: Cuff pressure too high. E6: Device malfunction. E7: Memory error.

When an error symbol appears: Stop measurement, remove cuff, wait 2-3 minutes, restart. If error persists, consult manual.

Battery & Power Indicators

Battery icon states: Full, half-full, empty, blinking.

  1. Full battery: Device has sufficient power.
  2. Half-full: Consider replacing batteries soon.
  3. Empty/blinking: Replace batteries immediately to ensure accuracy.
  4. AC adapter icon: Shows when using external power.

Tip: Use fresh alkaline batteries; remove if not using for extended periods.

Memory & Data Symbols

Supports storage of readings for one or multiple users.

  1. Memory recall: Press MEMORY button; book icon appears with reading number.
  2. User selection: U1, U2 symbols to toggle between user memories.
  3. Average: AVG symbol shows average of last 3 readings (or as programmed).
  4. Date/Time stamp: Clock symbol next to reading indicates when taken.
  5. Data transmission: Bluetooth/Wi-Fi icon for models with app connectivity.
  6. Memory full: Trash can or "FULL" symbol indicates no more storage space.

NOTE: Memory symbols vary by model; check manual for capacity.

Proper Cuff Placement

Cuff symbols guide correct placement.

Cuff with checkmark: Correct. Cuff with "X" or arrow: Incorrect. Arrows on cuff: Align with artery marker on arm. Wrist monitor symbols: Show proper wrist position relative to heart.

Care & Maintenance

Use only dry cloth to clean display and cuff. Do not immerse in water.

CAUTION! No water droplets symbol: Do not wash cuff in machine. Battery disposal: Follow local regulations (crossed-out trash symbol).

Safety Symbols

CE mark: Conformity with European standards. FCC mark: Compliance for US. Medical device symbol: Double-hexagon or "MD". Authorized representative symbol. Temperature limits: Snowflake/sun icons for operating range. Keep dry symbol: Umbrella with line through.

Troubleshooting Symbols

Symbol DisplayedPossible CauseCorrective Action
Blinking batteryLow batteryReplace all batteries with new ones.
E1 or cuff icon flashingCuff not connected/leakingReconnect cuff tube securely; check for damage.
Movement iconExcessive motionStay still, rest arm on table, retake measurement.
No displayDead batteries/powerReplace batteries; ensure AC adapter is plugged in.
Inconsistent readingsImproper cuff placementReposition cuff per manual diagrams; ensure snug fit.

Reset: Some models have reset pinhole; use paperclip to reset if symbols malfunction.

Support: 1-888-216-1333; www.omronhealthcare.com