omron blood pressure monitor manual bp7350

The Omron BP7350 is an upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a wide-range D-Ring cuff (22-42 cm), hypertension indicator, irregular heartbeat detection, memory storage for 100 readings with date/time stamp, body movement detection, and a large backlit display. Below are key sections for safety, features, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Display 6. Taking a Measurement 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit, D-Ring Cuff, AC Adapter, Instruction Manual, Storage Case.

FeatureDescription
IntelliSense TechnologyAutomatically adjusts cuff pressure for comfortable, accurate measurement
D-Ring Cuff (22-42 cm)Pre-formed cuff for easy self-application
Hypertension IndicatorDisplays warning symbol if reading exceeds WHO guidelines
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
100 Memory StorageStores up to 100 readings with date and time stamp
Body Movement DetectionAlerts user if movement is detected during measurement
Large Backlit DisplayEasy-to-read LCD with backlight for low-light conditions
Average ReadingCalculates average of last 3 readings taken within 10 minutes
AC Adapter/BatteryPowered by 4 AA batteries or included AC adapter
Clock FunctionBuilt-in clock for time/date stamp on readings

Installation & Setup

Unpack and inspect contents. Place on stable surface.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries matching polarity.
  2. Connect AC adapter: Plug into DC jack on side of unit (optional).
  3. Set date/time: Press CLOCK button, use MEMORY button to set values.
  4. Apply cuff: Wrap D-Ring cuff around bare upper arm 1-2 cm above elbow.

WARNING! Do not use on infants, small children, or persons with severe circulation disorders. Ensure cuff size is appropriate for your arm.

First-Time Use

Power on monitor; follow proper measurement procedure.

  1. Prepare for measurement: Sit quietly for 5 minutes, avoid caffeine, smoking, or exercise 30 minutes prior.
  2. Position arm: Rest arm on table with cuff at heart level.
  3. Start measurement: Press START/STOP button, remain still and quiet.
  4. Read results: Systolic, diastolic pressure, and pulse rate display automatically.
  5. Store reading: Press MEMORY button to save reading (optional).

CAUTION! Do not inflate cuff when not wrapped around arm. Keep unit away from electromagnetic fields.

Specifications

Controls and Display

Front Panel: START/STOP button, MEMORY button, CLOCK button, SET button.

Display Symbols: Systolic/Diastolic values, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, Body movement indicator, Memory number, Date/Time, Battery indicator, Average value icon.

Settings: Press SET to enter settings mode for time/date adjustment, memory review, and unit selection (mmHg/kPa).

Taking a Measurement

Follow proper procedure for accurate results.

  1. Sit comfortably with feet flat on floor, back supported.
  2. Wrap cuff securely around bare upper arm (tube downward).
  3. Position cuff at heart level, press START/STOP.
  4. Remain still and quiet during inflation/deflation.
  5. Read results when measurement completes (approx. 30 seconds).
  6. Press MEMORY to store if desired.
  7. Wait 2-3 minutes between measurements on same arm.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Stores up to 100 readings with date/time stamp.

  1. View memory: Press MEMORY button to scroll through stored readings.
  2. Average reading: Displays average of last 3 readings taken within 10 minutes.
  3. Delete memory: Hold SET button for 3 seconds while in memory mode to clear all readings.
  4. Memory full: Oldest reading automatically overwritten when memory reaches 100.

Note: Memory preserved when batteries removed (clock may reset).

Understanding Results

Interpret readings using standard guidelines.

CategorySystolic (mmHg)Diastolic (mmHg)
NormalLess than 120Less than 80
Prehypertension120-13980-89
Hypertension Stage 1140-15990-99
Hypertension Stage 2160 or higher100 or higher

Symbols: Hypertension indicator appears if reading exceeds 135/85 mmHg. Irregular heartbeat symbol appears if detected. Consult healthcare professional for interpretation.

Care & Maintenance

Clean with soft, dry cloth only. Do not immerse in water or use chemicals.

  1. Store in provided case when not in use.
  2. Remove batteries if not using for extended period.
  3. Check cuff regularly for wear or damage.
  4. Keep away from extreme temperatures, humidity, and direct sunlight.

CAUTION! Do not disassemble unit. No user-serviceable parts inside.

Regulatory Information

FDA Cleared: KXXXXXX. CE Marked: Meets European Medical Device Directive requirements. Manufactured by Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350. This device is intended for home use only. Not for professional medical use.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 AA batteries; ensure proper polarity.
Error E1 displayedCuff not wrapped properlyRewrap cuff securely; ensure tube connection is tight.
Error E2 displayedBody movement during measurementRemain still and retake measurement.
Error E3 displayedIrregular heartbeat detectedReading may be inaccurate; wait 5 minutes and retry.
Inconsistent readingsIncorrect positioningEnsure cuff at heart level; sit quietly before measuring.
Cuff doesn't inflateAir leakCheck cuff, tube, and connections for damage.
Memory not workingBattery failureReplace batteries; memory may be lost if batteries dead.

Reset: Remove batteries for 1 minute to reset unit.

Service: 1-800-634-4350; www.omronhealthcare.com