The Omron BP7350 is an upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable readings. It features a wide-range D-Ring cuff (22-42 cm), hypertension indicator, irregular heartbeat detection, memory storage for 100 readings with date/time stamp, body movement detection, and a large backlit display. Below are key sections for safety, features, setup, operation, and troubleshooting.
Key components: Main unit, D-Ring Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts cuff pressure for comfortable, accurate measurement |
| D-Ring Cuff (22-42 cm) | Pre-formed cuff for easy self-application |
| Hypertension Indicator | Displays warning symbol if reading exceeds WHO guidelines |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| 100 Memory Storage | Stores up to 100 readings with date and time stamp |
| Body Movement Detection | Alerts user if movement is detected during measurement |
| Large Backlit Display | Easy-to-read LCD with backlight for low-light conditions |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
| AC Adapter/Battery | Powered by 4 AA batteries or included AC adapter |
| Clock Function | Built-in clock for time/date stamp on readings |
Unpack and inspect contents. Place on stable surface.
WARNING! Do not use on infants, small children, or persons with severe circulation disorders. Ensure cuff size is appropriate for your arm.
Power on monitor; follow proper measurement procedure.
CAUTION! Do not inflate cuff when not wrapped around arm. Keep unit away from electromagnetic fields.
Front Panel: START/STOP button, MEMORY button, CLOCK button, SET button.
Display Symbols: Systolic/Diastolic values, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, Body movement indicator, Memory number, Date/Time, Battery indicator, Average value icon.
Settings: Press SET to enter settings mode for time/date adjustment, memory review, and unit selection (mmHg/kPa).
Follow proper procedure for accurate results.
Tip: Take measurements at same time each day for consistent tracking.
Stores up to 100 readings with date/time stamp.
Note: Memory preserved when batteries removed (clock may reset).
Interpret readings using standard guidelines.
| Category | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Normal | Less than 120 | Less than 80 |
| Prehypertension | 120-139 | 80-89 |
| Hypertension Stage 1 | 140-159 | 90-99 |
| Hypertension Stage 2 | 160 or higher | 100 or higher |
Symbols: Hypertension indicator appears if reading exceeds 135/85 mmHg. Irregular heartbeat symbol appears if detected. Consult healthcare professional for interpretation.
Clean with soft, dry cloth only. Do not immerse in water or use chemicals.
CAUTION! Do not disassemble unit. No user-serviceable parts inside.
FDA Cleared: KXXXXXX. CE Marked: Meets European Medical Device Directive requirements. Manufactured by Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350. This device is intended for home use only. Not for professional medical use.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries; ensure proper polarity. |
| Error E1 displayed | Cuff not wrapped properly | Rewrap cuff securely; ensure tube connection is tight. |
| Error E2 displayed | Body movement during measurement | Remain still and retake measurement. |
| Error E3 displayed | Irregular heartbeat detected | Reading may be inaccurate; wait 5 minutes and retry. |
| Inconsistent readings | Incorrect positioning | Ensure cuff at heart level; sit quietly before measuring. |
| Cuff doesn't inflate | Air leak | Check cuff, tube, and connections for damage. |
| Memory not working | Battery failure | Replace batteries; memory may be lost if batteries dead. |
Reset: Remove batteries for 1 minute to reset unit.
Service: 1-800-634-4350; www.omronhealthcare.com