The Omron BP7100 is an automatic upper arm blood pressure monitor with IntelliSense technology for accurate readings, a wide-range D-Ring cuff (22-42 cm), a large backlit display, hypertension indicator, irregular heartbeat detection, memory storage for up to 100 readings, date/time stamp, and averaging of last 3 readings. It is clinically validated and designed for home use. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with display, D-Ring Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the optimal level for comfortable measurement |
| D-Ring Cuff (22-42 cm) | Pre-formed cuff for easy self-application |
| Large Backlit Display | Easy-to-read results, even in low light |
| Hypertension Indicator | Displays symbol if reading is above WHO guidelines |
| Irregular Heartbeat Detection | Detects and displays symbol for pulse irregularities |
| Memory Storage | Stores up to 100 readings with date and time |
| Average of Last 3 Readings | Calculates and displays the average of the last 3 measurements |
| Clinically Validated | Meets standards of the European Society of Hypertension (ESH) |
| Power Options | 4 x AA batteries or AC adapter (included) |
| Automatic Power Off | Conserves battery life |
Read all instructions before use. For personal home use only.
WARNING! This device is not a toy. Keep away from children. Do not use if the cuff is damaged.
Familiarize yourself with the main components.
CAUTION! Ensure the air tube is securely connected before use.
Prepare the monitor for first use.
Tip: For most accurate results, take measurements at the same time each day.
Follow these steps for a proper reading.
WARNING! Do not inflate the cuff when it is not wrapped around your arm.
Icons and symbols on the screen.
Main Readings: Systolic Pressure (top number), Diastolic Pressure (middle number), Pulse Rate (bottom number).
Icons:
Hypertension Indicator ( ) - Appears if systolic ≥ 135 or diastolic ≥ 85 mmHg.
Irregular Heartbeat Symbol ( ) - Appears if an irregular rhythm is detected.
Memory Icon (M) - Indicates memory recall mode.
Average Icon (AVG) - Displayed when showing the average of last 3 readings.
Date & Time - Shows when the reading was taken.
Battery Icon - Indicates battery level.
Stores and recalls up to 100 readings.
Note: Memory is retained even when batteries are removed.
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not use the monitor in humid places such as a bathroom.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries, improper installation | Replace batteries; ensure correct polarity. |
| Error Code "E" appears | Cuff not attached, air leak | Secure cuff connection; ensure cuff is wrapped correctly. |
| Inaccurate reading | Improper posture, talking/moving | Sit correctly with arm at heart level; remain still and silent. |
| Memory not working | Memory full, button error | Clear memory; press MEMORY button firmly. |
| Cuff does not inflate | Blocked tube, weak batteries | Check tube for kinks; replace batteries. |
| Irregular Heartbeat symbol flashes | Pulse irregularity detected | Take another measurement. If symbol persists, consult your physician. |
Reset: Remove batteries for 1 minute to reset the unit.
Omron Healthcare, Inc. warrants this device to be free from defects in materials and workmanship for a period of Five (5) Years from the date of purchase. This warranty does not cover damage from misuse, accident, or unauthorized repair. For service under warranty, contact Omron Customer Support.
Customer Support:
Website: www.omronhealthcare.com
Phone: 1-800-634-4350
Address: Omron Healthcare, Inc., 1200 Lakeside Drive, Bannockburn, IL 60015 USA
Dispose of the device and batteries according to local regulations. Do not dispose of with household waste.