The Omron BP652 is a fully automatic upper arm blood pressure monitor with IntelliSense technology for comfortable inflation, a wide-range D-Ring cuff (22-42 cm), irregular heartbeat detection, hypertension indicator, 90-reading memory with date and time stamp, averaging of last 3 readings, and body movement detection. It features a large LCD display, one-touch operation, and is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, D-Ring Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the optimal level for comfortable measurement |
| D-Ring Cuff (22-42 cm) | Pre-formed, easy-to-wrap cuff for proper fit on the upper arm |
| Irregular Heartbeat Detection | Detects and displays an icon if an irregular heartbeat is detected during measurement |
| Hypertension Indicator | Displays a symbol if systolic/diastolic readings are above WHO guidelines |
| 90-Reading Memory | Stores up to 90 readings with date and time stamp |
| Average of Last 3 Readings | Calculates and displays the average of the last 3 readings taken within 10 minutes |
| Body Movement Detection | Alerts user if excessive movement is detected during measurement |
| One-Touch Operation | Simple START/STOP button for easy use |
| Large LCD Display | Easy-to-read backlit display with clear icons |
| Power Options | 4 x AA batteries or AC adapter (included) |
Read all instructions before use. For personal home use only.
WARNING! This device is not a treatment device. Measurements are for reference only. Always consult a physician for diagnosis and treatment.
Before first use, install batteries or connect AC adapter, set date and time.
Note: If using AC adapter, plug it into the jack on the right side of the unit before connecting to power outlet. Using the AC adapter disables battery power.
For accurate results, measure at the same time each day, in a quiet place, while seated.
Tip: For consistent results, take 2-3 measurements, waiting 2-3 minutes between each. The unit will average the last 3 readings taken within 10 minutes if this feature is activated.
The LCD shows various icons and values:
| Symbol | Meaning |
|---|---|
| SYS / DIA | Systolic / Diastolic pressure (mmHg) |
| Pulse Symbol | Pulse rate (beats per minute) |
| Irregular Heartbeat Icon | Detected irregular rhythm during measurement |
| Hypertension Indicator | Systolic ≥135 mmHg or Diastolic ≥85 mmHg (based on WHO) |
| Body Movement Icon | Excessive movement detected; retake measurement |
| Memory Index (e.g., 01) | Current memory position (1-90) |
| Date & Time | Stamp of when reading was taken |
| Average Icon | Displayed when showing average of last 3 readings |
| Battery Icon | Indicates battery level (replace when low) |
| AC Adapter Icon | Displayed when using AC power |
The device stores up to 90 readings with date and time.
Note: When memory is full (90 readings), the oldest reading is automatically deleted to store a new one.
Proper care ensures accuracy and longevity.
CAUTION! Do not disassemble or attempt to repair the unit. There are no user-serviceable parts inside.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. CE marked, indicating conformity with European health, safety, and environmental protection standards. Manufactured for Omron Healthcare, Inc. For support in the US and Canada, visit www.omronhealthcare.com or call 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display when START button pressed | Dead batteries, loose AC adapter | Replace all 4 batteries; ensure AC adapter is firmly connected. |
| Error Code "E" appears | Cuff not attached, air leak, tube kinked | Ensure cuff is plugged in correctly; check tube for kinks; rewrap cuff snugly. |
| Error Code "Er1" or "Er2" | Excessive movement during measurement | Remain still and quiet; retake measurement. |
| Inconsistent readings | Incorrect cuff position, talking/moving, recent activity | Ensure cuff is at heart level on bare arm; rest 5 min before measuring; remain still. |
| Memory not displaying | Memory cleared or unit malfunction | Check if memory was accidentally cleared. If problem persists, contact service. |
| Irregular Heartbeat symbol flashes | Irregular rhythm detected | Consult your physician if this symbol appears frequently. |
| Cuff inflates too much or too little | IntelliSense calibration issue | Ensure cuff is applied correctly. Unit self-calibrates; if problem continues, contact service. |
Reset: Remove batteries and AC adapter for 1 minute, then reinstall.
Service: Do not attempt repairs. For service, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com.