Omron Blood Pressure Monitor Manual BP6350

The Omron BP6350 is an upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable measurement. It features a large, easy-to-read display, memory storage for multiple users, hypertension detection, irregular heartbeat detection, body movement detection, and date/time stamp. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Parts Identification 4. Initial Setup 5. Taking a Measurement 6. Memory Function 7. Special Features 8. Care & Maintenance 9. Specifications 10. Troubleshooting

Features at a Glance

Key components: Main unit with display, Arm cuff, AC adapter, Instruction manual, Storage case.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to the ideal level for accurate measurement
Dual User MemoryStores up to 100 readings per user (200 total)
Hypertension IndicatorDisplays symbol if systolic/diastolic readings are high
Irregular Heartbeat DetectionDetects and displays symbol for irregular heartbeats during measurement
Body Movement DetectionAlerts if movement is detected during measurement
Large LCD DisplayShows systolic, diastolic, pulse, date/time, and user indicator
Date/Time StampRecords measurement date and time for tracking
Cuff Wrap GuideIndicates proper cuff placement
AC Adapter PortFor powering the device (batteries also supported)
START/STOP ButtonInitiates and stops measurement

Safety Information

Read all instructions before use.

  1. Do not use on infants, small children, or persons unable to express themselves.
  2. Consult your physician before use if you have arrhythmia, other circulatory problems, or are pregnant.
  3. Do not use the monitor on an injured arm or after surgery.
  4. Do not inflate the cuff when not wrapped around the arm.

WARNING! This device is not a substitute for professional medical diagnosis. Measurements are for monitoring purposes only.

Parts Identification

Front Panel: LCD Display, START/STOP Button, Memory Button, User Button (1/2), Clock Button.

Display Symbols: User 1/2 indicator, Systolic pressure, Diastolic pressure, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, Body movement symbol, Low battery, Memory full, Date/Time.

Side/Rear: AC adapter jack, Air plug connector, Cuff storage clip.

Initial Setup

Insert batteries or connect AC adapter.

  1. Set date and time: Press CLOCK button, use START/STOP to adjust values, press MEMORY to confirm.
  2. Select user: Press USER button to select User 1 or User 2 before measurement.
  3. Apply cuff: Place cuff on bare upper arm 1-2 cm above elbow. Ensure tube runs down center of arm.
  4. Position arm: Rest arm on table with cuff at heart level. Sit still with feet flat on floor.

CAUTION! Ensure cuff is correctly sized and positioned for accurate readings.

Taking a Measurement

Remain still and quiet during measurement.

  1. Select user: Press USER button (User 1 or User 2).
  2. Wrap cuff: Secure snugly but not too tight.
  3. Press START/STOP: Unit inflates automatically. Remain still.
  4. Reading displayed: Systolic, diastolic, and pulse appear. Hypertension/Irregular heartbeat symbols if detected.
  5. Cuff deflates: Automatically after measurement.
  6. Power off: Unit turns off automatically after 1 minute.

Tip: Avoid eating, smoking, or exercising 30 minutes before measurement.

Memory Function

Stores 100 readings per user.

  1. View memory: Press MEMORY button. Display shows average of last 3 readings.
  2. Scroll readings: Press START/STOP to scroll through individual readings with date/time.
  3. Clear memory: Hold MEMORY button for 3 seconds until "CLR" flashes. Press START/STOP to clear current user's memory.
  4. Switch users: Press USER button to view other user's memory.

Note: Memory full indicator appears when 100 readings are stored.

Special Features

Hypertension Detection: Symbol appears if systolic ≥135 mmHg or diastolic ≥85 mmHg.

Irregular Heartbeat Detection: Symbol appears if irregular rhythm is detected during measurement.

Body Movement Detection: Measurement pauses and symbol appears if movement is detected.

Average Reading: Displays average of last 3 readings taken within last 10 minutes.

Care & Maintenance

Clean with soft, dry cloth. Do not immerse in water or use chemicals.

  1. Cuff care: Wipe with damp cloth and mild detergent. Air dry completely.
  2. Storage: Store in provided case in cool, dry place.
  3. Batteries: Replace when low battery symbol appears. Use 4 AA batteries.
  4. AC adapter: Use only specified adapter (HEM-AC-AD1).

CAUTION! Do not disassemble or attempt repairs. No user-serviceable parts inside.

Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace batteries or connect AC adapter
Error E1 displayedCuff not wrapped properlyRewrap cuff correctly and restart
Error E2 displayedMovement during measurementRemain still and retry
Inconsistent readingsWrong cuff positionEnsure cuff is at heart level
Memory not storingMemory fullClear memory or switch users
Cuff doesn't inflateAir leak in tube/cuffCheck connections; replace if damaged
Irregular heartbeat symbol always onPossible arrhythmiaConsult your physician

Reset: Remove batteries for 1 minute to reset unit.

Service: For service, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com