Omron Blood Pressure Monitor Manual BP5250

The Omron BP5250 is an upper-arm blood pressure monitor featuring IntelliSense technology for accurate, comfortable readings. It includes a large, easy-to-read display, memory storage for multiple users, hypertension detection, irregular heartbeat detection, and a body movement indicator. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Parts Identification 4. Initial Setup 5. Taking a Measurement 6. Memory Function 7. Understanding Your Readings 8. Care & Maintenance 9. Battery Information 10. Troubleshooting 11. Specifications & Warranty

Features at a Glance

Key components: Main unit with display, Arm cuff, AC adapter port, Memory buttons, START/STOP button.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to the optimal pressure for a comfortable reading
Hypertension IndicatorDisplays a symbol if your reading is in the hypertensive range
Irregular Heartbeat DetectorDetects and displays an icon for possible irregular heartbeats during measurement
Body Movement IndicatorAlerts you if excessive movement is detected during measurement
Multi-User MemoryStores up to 100 readings for each of two users
Large DisplayEasy-to-read backlit LCD with date and time
Average ReadingCalculates the average of the last three readings taken in the last 10 minutes
AC Adapter CompatibleCan be powered by AC adapter (sold separately) or batteries
Cuff Wrap GuideVisual indicator to ensure proper cuff placement
Automatic Power OffConserves battery life by turning off after 1 minute of inactivity

Safety Information

Read all instructions before use. For accurate readings and safety:

  1. Do not use on infants, young children, or persons who cannot express themselves.
  2. Do not use during periods of physical irregularity (e.g., after exercise, bathing, eating, or drinking alcohol/caffeine).
  3. Consult your physician before use if you have arrhythmia, pre-eclampsia, or other circulatory disorders.
  4. Do not use the monitor on an injured or sore arm.
  5. Keep the monitor away from children and pets.

WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of readings.

Parts Identification

Familiarize yourself with the monitor components.

  1. Main Unit: Contains display, control buttons, and internal pump.
  2. Display: Shows systolic/diastolic pressure, pulse, icons, date/time, and memory.
  3. Arm Cuff: Wraps around upper arm with Velcro closure and air tube.
  4. Air Tube: Connects cuff to main unit.
  5. START/STOP Button: Initiates and stops measurement.
  6. Memory Buttons (User 1/User 2): Select user memory and recall stored readings.
  7. AC Adapter Port: For optional external power (Model EA11A).
  8. Battery Compartment: Holds 4 AA batteries.

CAUTION! Do not bend or kink the air tube. Ensure cuff is not twisted.

Initial Setup

Prepare the monitor for first use.

  1. Insert Batteries: Open battery compartment, insert 4 new AA batteries observing polarity.
  2. Set Date and Time: Press and hold the User 1 and User 2 buttons simultaneously for 3 seconds. Use START/STOP to adjust values.
  3. Apply Cuff: Sit quietly for 5 minutes. Wrap cuff on bare upper arm 1-2 cm above elbow. Ensure tube runs down center of arm.
  4. Position: Sit with back straight, feet flat, arm supported at heart level. Remain still and quiet.

Tip: For most accurate results, take measurements at the same time each day.

Taking a Measurement

Follow these steps for a proper reading.

  1. Press the User 1 or User 2 button to select your memory profile.
  2. Wrap the cuff correctly (see Initial Setup).
  3. Press the START/STOP button. The monitor will inflate automatically.
  4. Remain still and quiet until measurement is complete and cuff deflates.
  5. Read your systolic/diastolic pressure and pulse rate on the display.
  6. Note any icons (irregular heartbeat, hypertension, body movement).
  7. The reading will automatically save to the selected user's memory.
  8. To turn off, press START/STOP again or wait for auto power-off.

WARNING! Do not inflate cuff without it being wrapped on your arm.

Memory Function

Store and review past readings.

Note: Memory is retained when batteries are removed.

Understanding Your Readings

Interpret the display symbols and values.

Symbol/ValueMeaning
Systolic Pressure (top number)Pressure in arteries when heart beats.
Diastolic Pressure (bottom number)Pressure in arteries when heart rests between beats.
Pulse RateHeartbeats per minute.
Irregular Heartbeat IconAppears if an irregular rhythm is detected. Consult physician if frequent.
Hypertension IndicatorAppears if systolic ≥135 mmHg or diastolic ≥85 mmHg.
Body Movement IconAppears if excessive movement is detected. Retake measurement.
Memory IconIndicates which user memory is active (1 or 2).
Low Battery IconReplace batteries soon.

Care & Maintenance

Unplug AC adapter (if used) and remove batteries before cleaning.

  1. Wipe main unit and cuff with a soft, dry cloth.
  2. Do not immerse in water or use harsh chemicals.
  3. Store in a cool, dry place away from direct sunlight and extreme temperatures.
  4. Do not store with the cuff tightly wrapped.
  5. Inspect cuff and tube periodically for cracks or wear.

CAUTION! Do not disassemble or attempt to repair the unit. Contact Omron for service.

Battery Information

Note: Remove batteries if the monitor will not be used for 3 months or longer.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteries, improper insertionReplace all 4 batteries; ensure correct polarity.
Error Code "E" appearsCuff not attached, air leak, tube blockedEnsure cuff is connected; wrap cuff correctly; check tube for kinks.
Inaccurate readingImproper posture, cuff position, recent activitySit correctly; reposition cuff 1-2 cm above elbow; rest 5 min before measuring.
Memory not storingMemory full, wrong user selectedClear memory; press correct User button before measuring.
Cuff does not inflateLow batteries, tube not connectedReplace batteries; ensure tube is fully inserted into main unit.
Irregular Heartbeat symbol flashesArrhythmia detected during measurementRemain still and retake. If symbol appears frequently, consult your physician.

Reset: Remove batteries, wait 1 minute, reinsert batteries.

Service: 1-800-634-4350; www.omronhealthcare.com