Omron Blood Pressure Monitor M2 Basic Manual

The Omron M2 Basic is an automatic upper-arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate readings, one-touch operation, a large display with hypertension indicator, memory storage for the last reading, and a comfortable D-ring cuff. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Package Contents 4. Device Overview 5. Before First Use 6. Taking a Measurement 7. Understanding the Display 8. Memory Function 9. Care & Maintenance 10. Specifications 11. Troubleshooting

Features at a Glance

Key components: Main unit with display, D-ring cuff, air tube, instruction manual, and storage case.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to the optimal pressure for accurate measurement
One-Touch OperationStart measurement with a single button press
Large LCD DisplayEasy-to-read results for systolic, diastolic pressure, and pulse
Hypertension IndicatorDisplays symbol if reading exceeds WHO guidelines
Last Reading MemoryStores the most recent measurement for quick comparison
Comfortable D-Ring Cuff22-32 cm cuff for easy self-application
Automatic Power OffConserves battery life by turning off after use
Irregular Heartbeat DetectionSymbol appears if an irregular rhythm is detected during measurement

Safety Precautions

Read all instructions before use. For personal home use only.

  1. Do not use on infants, small children, or persons unable to express themselves.
  2. Do not use during physical exercise or immediately after.
  3. Do not wrap cuff over clothing; apply directly to bare upper arm.
  4. Remain still and quiet during measurement; do not talk.
  5. Consult your physician for interpretation of readings and diagnosis.

WARNING! Not suitable for use with pacemakers or other electronic implants. Do not use in oxygen-rich environments.

Package Contents

Unpack and verify all items are present.

CAUTION! Do not discard packaging until all items are checked. Keep manual for future reference.

Device Overview

Front Panel: START/STOP button, Memory button, LCD display. Cuff: D-ring, metal clasp, air tube connector, artery mark.

Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, Memory icon, Battery low indicator.

Back: Battery compartment, air release valve.

Before First Use

Prepare the device for initial measurement.

  1. Insert Batteries: Open compartment on back, insert 4 AA batteries as indicated.
  2. Apply Cuff: Sit quietly for 5 minutes. Expose left upper arm (recommended). Place cuff with tube facing down and artery mark over brachial artery.
  3. Secure Cuff: Pass end through D-ring and tighten snugly (1 finger should fit between cuff and arm).
  4. Position: Rest arm on table with cuff at heart level. Sit with back straight, feet flat.

Tip: Avoid eating, smoking, or drinking caffeine 30 minutes before measurement.

Taking a Measurement

Follow these steps for an accurate reading.

  1. Press START/STOP button. All display symbols will appear briefly.
  2. Cuff will inflate automatically. Remain still and do not flex arm.
  3. As cuff deflates, measurement values will appear.
  4. When measurement is complete, cuff deflates fully. Systolic, diastolic, and pulse readings are displayed.
  5. To view last reading, press MEMORY button.
  6. Device turns off automatically after 1 minute.

WARNING! Do not inflate cuff manually. If uncomfortable, press START/STOP to stop.

Understanding the Display

Reading example: 120/80 (65).

Memory Function

Stores the last measurement only.

  1. After taking a reading, press MEMORY button to recall it.
  2. The "M" icon appears with the stored values.
  3. Taking a new measurement overwrites the previous memory.
  4. Memory is cleared when batteries are removed.

Note: For tracking trends over time, record readings in a log or use a model with expanded memory.

Care & Maintenance

Unplug air tube and remove batteries before cleaning.

  1. Wipe main unit and cuff with a soft, dry cloth.
  2. Do not immerse in water or use detergents.
  3. Store in provided case in a cool, dry place.
  4. Avoid extreme temperatures, humidity, dust, and direct sunlight.
  5. Replace batteries when low indicator appears.

CAUTION! Do not disassemble or attempt repairs. Have unit serviced by authorized personnel only.

Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 AA batteries with new ones.
Error Code "E"Cuff not attached/leakingEnsure cuff is connected securely. Check tube for damage.
Error Code "Er"Measurement errorRemain still and retry. Ensure cuff is at heart level.
Inconsistent readingsIncorrect cuff positionReapply cuff with artery mark directly over brachial artery.
Cuff does not inflateBlocked air tubeStraighten tube. Ensure it is not kinked or pinched.
Irregular heartbeat symbol appears frequentlyPossible arrhythmiaConsult your physician for evaluation.

Reset: Remove batteries for 1 minute, then reinsert.

Service: For support, visit www.omron-healthcare.com or contact your local Omron representative.