The Omron HEM 7130 is an automatic upper-arm blood pressure monitor with IntelliSense technology for accurate and comfortable measurement. It features a large, easy-to-read display, memory storage for multiple users, hypertension detection indicator, irregular heartbeat detection, and body movement detection. Powered by 4 AA batteries or AC adapter (optional). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with display, Arm cuff with D-Ring, AC adapter port, Battery compartment, START/STOP button, Memory button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol during measurement |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| Memory Function | Stores up to 14 measurements for each of 2 users |
| Large LCD Display | Easy-to-read results with date and time stamp |
| Cuff Wrap Guide | Indicates proper cuff placement |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be used with optional AC adapter (HEM-AC-ADP1) |
| World Health Organization (WHO) Indicator | Color-coded bar graph shows blood pressure classification |
Read all instructions before use. Consult physician for proper diagnosis and treatment.
WARNING! This device is for home monitoring only, not for professional medical diagnosis. Always follow your doctor's instructions.
Front Panel: LCD display, START/STOP button, Memory button. Side: AC adapter port. Bottom: Battery compartment. Cuff: Arm cuff with D-Ring, air tube, metal ring.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator (1 or 2), Memory symbol, Hypertension indicator, Irregular heartbeat symbol, Body movement symbol, Low battery symbol, Date/Time.
CAUTION! Ensure cuff is properly sized for your arm circumference (22-32 cm). Using wrong size may affect accuracy.
Power on device; set date and time.
CAUTION! Use only recommended batteries. Remove batteries if not using for extended period.
For accurate results, rest for 5 minutes before measuring.
Tip: Take measurements at same time each day for consistent tracking.
Stores 14 readings for each of 2 users with date/time stamp.
Note: When memory is full, oldest reading is automatically deleted for new one.
Normal range: Systolic <120 mmHg, Diastolic <80 mmHg (WHO guidelines).
| Category | Systolic (mmHg) | Diastolic (mmHg) | Indicator |
|---|---|---|---|
| Normal | <120 | <80 | Green zone |
| Prehypertension | 120-139 | 80-89 | Yellow zone |
| Hypertension Stage 1 | 140-159 | 90-99 | Orange zone |
| Hypertension Stage 2 | ≥160 | ≥100 | Red zone |
Symbols: Hypertension indicator appears if reading exceeds 135/85 mmHg. Irregular heartbeat symbol appears if irregular rhythm detected. Body movement symbol appears if excessive movement during measurement.
Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.
CAUTION! Do not disassemble or attempt repairs. Contact authorized service center.
FDA Cleared: K003456. CE Mark: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © Omron Healthcare. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
Disposal: Dispose according to local regulations. Do not dispose with household waste. Remove batteries before disposal.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones |
| Error E1, E2, E3 | Cuff not wrapped properly | Re-wrap cuff correctly; ensure tube connected |
| Error E4, E5 | Movement during measurement | Remain still and quiet; retake measurement |
| Inconsistent readings | Wrong cuff position | Ensure cuff at heart level; rest 5 min before measuring |
| Memory not working | Memory full or corrupted | Clear memory; ensure correct user selected |
| Cuff doesn't inflate | Air leak or blockage | Check tube connections; ensure cuff not twisted |
| Display dim | Low batteries | Replace batteries immediately |
Reset: Remove batteries for 1 minute, then reinsert to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com