Omron Blood Pressure Monitor HEM 7130 Manual

The Omron HEM 7130 is an automatic upper-arm blood pressure monitor with IntelliSense technology for accurate and comfortable measurement. It features a large, easy-to-read display, memory storage for multiple users, hypertension detection indicator, irregular heartbeat detection, and body movement detection. Powered by 4 AA batteries or AC adapter (optional). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Parts Identification 4. Specifications 5. Initial Setup 6. Taking a Measurement 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with display, Arm cuff with D-Ring, AC adapter port, Battery compartment, START/STOP button, Memory button.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for comfortable measurement
Hypertension IndicatorDisplays warning symbol if systolic/diastolic readings are high
Irregular Heartbeat DetectionDetects and displays irregular heartbeat symbol during measurement
Body Movement DetectionAlerts if excessive movement is detected during measurement
Memory FunctionStores up to 14 measurements for each of 2 users
Large LCD DisplayEasy-to-read results with date and time stamp
Cuff Wrap GuideIndicates proper cuff placement
Automatic Power OffConserves battery life by turning off after 1 minute of inactivity
AC Adapter CompatibleCan be used with optional AC adapter (HEM-AC-ADP1)
World Health Organization (WHO) IndicatorColor-coded bar graph shows blood pressure classification

Safety Precautions

Read all instructions before use. Consult physician for proper diagnosis and treatment.

  1. Do not use on infants, children, or persons unable to express themselves.
  2. Do not use during or immediately after physical exercise or bathing.
  3. Do not wrap cuff over clothing or apply to injured arm.
  4. Do not disassemble or modify the device.
  5. Keep device away from children and pets.

WARNING! This device is for home monitoring only, not for professional medical diagnosis. Always follow your doctor's instructions.

Parts Identification

Front Panel: LCD display, START/STOP button, Memory button. Side: AC adapter port. Bottom: Battery compartment. Cuff: Arm cuff with D-Ring, air tube, metal ring.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator (1 or 2), Memory symbol, Hypertension indicator, Irregular heartbeat symbol, Body movement symbol, Low battery symbol, Date/Time.

CAUTION! Ensure cuff is properly sized for your arm circumference (22-32 cm). Using wrong size may affect accuracy.

Specifications

Initial Setup

Power on device; set date and time.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Set date and time: Press and hold Memory button for 3 seconds, use START/STOP to adjust.
  3. Attach cuff: Connect air tube to main unit until it clicks.
  4. Test operation: Press START/STOP to ensure device powers on.

CAUTION! Use only recommended batteries. Remove batteries if not using for extended period.

Taking a Measurement

For accurate results, rest for 5 minutes before measuring.

  1. Sit comfortably: Feet flat on floor, back supported, arm at heart level.
  2. Wrap cuff: Place cuff 1-2 cm above elbow, align artery marker with brachial artery.
  3. Secure cuff: Tighten so 1-2 fingers fit between cuff and arm.
  4. Start measurement: Press START/STOP, remain still and quiet during inflation/deflation.
  5. Read results: Systolic, diastolic, and pulse rate display automatically.
  6. Power off: Device turns off automatically after 1 minute.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Stores 14 readings for each of 2 users with date/time stamp.

  1. Select user: Press Memory button to toggle between User 1 and User 2.
  2. Store reading: After measurement, reading is automatically stored for selected user.
  3. Recall memory: Press Memory button twice quickly to view stored readings.
  4. Clear memory: Press and hold Memory button for 5 seconds while in memory mode.

Note: When memory is full, oldest reading is automatically deleted for new one.

Understanding Results

Normal range: Systolic <120 mmHg, Diastolic <80 mmHg (WHO guidelines).

CategorySystolic (mmHg)Diastolic (mmHg)Indicator
Normal<120<80Green zone
Prehypertension120-13980-89Yellow zone
Hypertension Stage 1140-15990-99Orange zone
Hypertension Stage 2≥160≥100Red zone

Symbols: Hypertension indicator appears if reading exceeds 135/85 mmHg. Irregular heartbeat symbol appears if irregular rhythm detected. Body movement symbol appears if excessive movement during measurement.

Care & Maintenance

Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.

  1. Store in cool, dry place away from direct sunlight.
  2. Remove batteries if not using for 3 months or more.
  3. Clean cuff with mild detergent if soiled; air dry completely.
  4. Avoid bending air tube sharply or pulling forcefully.
  5. Do not immerse any part in water.

CAUTION! Do not disassemble or attempt repairs. Contact authorized service center.

Regulatory Information

FDA Cleared: K003456. CE Mark: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © Omron Healthcare. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Disposal: Dispose according to local regulations. Do not dispose with household waste. Remove batteries before disposal.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries with new ones
Error E1, E2, E3Cuff not wrapped properlyRe-wrap cuff correctly; ensure tube connected
Error E4, E5Movement during measurementRemain still and quiet; retake measurement
Inconsistent readingsWrong cuff positionEnsure cuff at heart level; rest 5 min before measuring
Memory not workingMemory full or corruptedClear memory; ensure correct user selected
Cuff doesn't inflateAir leak or blockageCheck tube connections; ensure cuff not twisted
Display dimLow batteriesReplace batteries immediately

Reset: Remove batteries for 1 minute, then reinsert to reset device.

Service: 1-800-634-4350; www.omronhealthcare.com