The Omron BP791IT is an advanced upper arm blood pressure monitor with Bluetooth® connectivity, designed for home use. It features IntelliWrap™ Cuff technology for accurate positioning, detects irregular heartbeats, stores up to 200 readings for two users, includes morning hypertension detection, and syncs data to the free OMRON Connect app for tracking and sharing with healthcare providers. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with display, IntelliWrap™ Cuff (22-42 cm), AC adapter, storage case, instruction manual, and quick start guide.
| Feature | Description |
|---|---|
| IntelliWrap™ Cuff | Pre-formed 360° cuff for easy, correct placement |
| Bluetooth® Connectivity | Wirelessly syncs readings to OMRON Connect app |
| Dual User Memory | Stores up to 200 readings total (100 per user) |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol during measurement |
| Morning Hypertension Indicator | Highlights readings taken in the morning (6 am - 10 am) |
| Body Movement Detection | Alerts if excessive movement affects accuracy |
| AC Adapter Port | For powering the device (4 AA batteries also supported) |
| START/STOP Button | Initiates and stops measurement |
| MEMORY Button | Reviews stored readings |
| USER Button | Switches between User 1 and User 2 |
Read all instructions before use. For accurate readings and safety:
WARNING! This device is for home use only, not for professional medical diagnosis. Consult your doctor for interpretation of readings.
Prepare the monitor for first use.
CAUTION! Do not use rechargeable batteries. Use only recommended battery type.
Front Panel: START/STOP button, MEMORY button, USER button, LCD display.
Display Icons: User 1/2, Systolic/Diastolic pressure, Pulse rate, Irregular Heartbeat symbol, Morning Indicator, Body Movement Detection, Bluetooth® connection, Battery level, Memory full, Error codes.
Settings via App: Time/date, target ranges, guest mode, data sharing settings.
For most accurate results, measure at the same time each day, before exercise or eating.
Tip: Avoid talking or moving during measurement.
The app provides tracking, trends, and sharing capabilities.
Note: App features may vary by region and device compatibility.
Viewing Stored Readings on Device:
Deleting All Data: Press and hold the MEMORY and USER buttons simultaneously for 3 seconds. "CLR" appears, then all data for the selected user is erased.
Unplug AC adapter or remove batteries before cleaning.
CAUTION! Do not wash the cuff. Do not disassemble the monitor.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. CE marked, conforming to EU medical device regulations. Bluetooth® word mark and logos are registered trademarks of Bluetooth SIG, Inc. OMRON Healthcare, Inc. Copyright © 2023. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries, improper installation | Replace batteries; ensure correct polarity; try AC adapter. |
| Error Code "E" | Cuff not attached, tube blocked | Ensure cuff is connected properly; check tube for kinks. |
| Inconsistent readings | Improper posture, movement, cuff position | Follow measurement instructions precisely; ensure cuff at heart level. |
| Bluetooth® not connecting | Out of range, phone Bluetooth® off, pairing mode not active | Bring devices within 2m; enable phone Bluetooth®; hold MEMORY for 3 sec to enter pairing. |
| Irregular Heartbeat symbol appears frequently | Possible arrhythmia | Consult your physician with your reading history. |
| Cuff does not inflate | Batteries low, leak in cuff/tube | Replace batteries; inspect cuff and tube for damage. |
Reset: Remove batteries for 1 minute to perform a soft reset.
Service: Do not attempt to repair. Contact OMRON customer service at 1-800-634-4350 or www.omronhealthcare.com.