The Omron BP786 is an advanced upper arm blood pressure monitor featuring IntelliWrap™ Cuff technology for accurate positioning, TrueRead™ technology for consistent readings, dual display for easy viewing, irregular heartbeat detection, hypertension indicator, 200-user memory with date/time stamp, and AC adapter compatibility. It is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Package Contents 4. Device Overview 5. Initial Setup 6. Taking a Measurement 7. Understanding Results 8. Memory & Data Management 9. Care & Maintenance 10. Specifications 11. Troubleshooting

Features at a Glance

Key components: Main unit with dual LCD display, IntelliWrap™ Cuff (22-42 cm), AC adapter, storage case, instruction manual, and quick start guide.

FeatureDescription
IntelliWrap™ Cuff360° fit for easy, accurate placement on left arm
TrueRead™ TechnologyEnsures consistent, accurate readings
Dual DisplayShows systolic, diastolic, pulse, and date/time simultaneously
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
Hypertension IndicatorHighlights readings above normal range
200-User MemoryStores readings with date and time stamp
AC Adapter CompatibleFor continuous use without batteries
Clinically ValidatedMeets accuracy standards of major health organizations
Body Movement DetectionAlerts if movement affects measurement
Cuff Wrap GuideVisual indicator for correct cuff tightness

Safety Information

Read all instructions before use. For personal home use only.

  1. Do not use on infants, children, or persons unable to express themselves.
  2. Consult physician before use if you have arrhythmia, blood disease, or are pregnant.
  3. Do not use on injured or sore arm.
  4. Do not use while operating vehicles or machinery.
  5. Keep device and accessories away from children.

WARNING! Not for medical diagnosis. Consult healthcare professional for interpretation of readings.

Package Contents

Unpack and verify all items are present.

CAUTION! Do not discard packaging until all items are confirmed.

Device Overview

Front Panel: START/STOP button, MEMORY button, USER button, SET button, LCD display. Cuff: Air tube connector, Velcro closure, artery marker, range check guide.

Display Icons: Systolic/Diastolic/Pulse readings, User indicator, Memory full, Irregular heartbeat, Hypertension, Cuff wrap guide, Low battery, Date/Time.

Initial Setup

Prepare device for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter (optional): Plug into DC jack on side of unit.
  3. Set date/time: Press SET, use arrows to adjust, press SET to confirm.
  4. Select user: Press USER to toggle between User 1 and User 2.

Tip: Use AC adapter for prolonged use to conserve batteries.

Taking a Measurement

For most accurate results, measure at same time each day.

  1. Rest quietly for 5 minutes before measuring.
  2. Sit correctly: Feet flat, back straight, arm supported at heart level.
  3. Apply cuff: Expose left arm, align artery marker with brachial artery, wrap snugly.
  4. Start measurement: Press START/STOP. Cuff inflates automatically.
  5. Remain still and quiet until measurement completes and cuff deflates.
  6. View results: Systolic, diastolic, and pulse display with indicators if applicable.
  7. Power off: Unit turns off automatically after 1 minute.

WARNING! Do not move or talk during measurement.

Understanding Results

Refer to chart below. Consult physician for personal target ranges.

CategorySystolic (mmHg)Diastolic (mmHg)
NormalLess than 120and Less than 80
Elevated120-129and Less than 80
Hypertension Stage 1130-139or 80-89
Hypertension Stage 2140 or higheror 90 or higher
Hypertensive CrisisHigher than 180and/or Higher than 120

Icons: Hypertension icon appears if reading is above normal. Irregular heartbeat icon appears if detected.

Memory & Data Management

Stores 100 readings per user (2 users total).

  1. View memory: Press MEMORY button to scroll through stored readings with date/time.
  2. Clear memory: While in memory mode, press and hold SET for 3 seconds.
  3. Average reading: Displays average of last 3 readings taken in last 10 minutes.

Note: Memory full icon appears when 100 readings are stored for a user.

Care & Maintenance

Unplug AC adapter and remove batteries before cleaning.

  1. Clean cuff: Use mild soap and damp cloth. Air dry completely.
  2. Clean unit: Wipe with soft, dry cloth. Do not use solvents.
  3. Storage: Keep in provided case in cool, dry place away from direct sunlight.
  4. Battery replacement: Replace when low battery icon appears.

CAUTION! Do not immerse unit or cuff in water. Do not wash cuff in washing machine.

Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace batteries or use AC adapter.
Error Code E1Cuff not wrapped correctlyRewrap cuff, ensure artery marker is aligned.
Error Code E2Movement during measurementRemain still and retake measurement.
Error Code E3Cuff pressure too highRemove cuff, restart. Check for obstruction.
Inconsistent readingsIncorrect posture or timingRest 5 minutes, sit correctly, measure at consistent time.
Cuff does not inflateAir tube not connectedEnsure tube is securely connected to unit.
Memory full100 readings storedClear memory or review and delete old readings.

Reset: Remove batteries and AC adapter for 1 minute to reset unit.

Service: For technical support, visit www.omronhealthcare.com or call 1-800-634-4350.