The Omron BP786 is an advanced upper arm blood pressure monitor featuring IntelliWrap™ Cuff technology for accurate positioning, TrueRead™ technology for consistent readings, dual display for easy viewing, irregular heartbeat detection, hypertension indicator, 200-user memory with date/time stamp, and AC adapter compatibility. It is clinically validated for accuracy. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with dual LCD display, IntelliWrap™ Cuff (22-42 cm), AC adapter, storage case, instruction manual, and quick start guide.
| Feature | Description |
|---|---|
| IntelliWrap™ Cuff | 360° fit for easy, accurate placement on left arm |
| TrueRead™ Technology | Ensures consistent, accurate readings |
| Dual Display | Shows systolic, diastolic, pulse, and date/time simultaneously |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | Highlights readings above normal range |
| 200-User Memory | Stores readings with date and time stamp |
| AC Adapter Compatible | For continuous use without batteries |
| Clinically Validated | Meets accuracy standards of major health organizations |
| Body Movement Detection | Alerts if movement affects measurement |
| Cuff Wrap Guide | Visual indicator for correct cuff tightness |
Read all instructions before use. For personal home use only.
WARNING! Not for medical diagnosis. Consult healthcare professional for interpretation of readings.
Unpack and verify all items are present.
CAUTION! Do not discard packaging until all items are confirmed.
Front Panel: START/STOP button, MEMORY button, USER button, SET button, LCD display. Cuff: Air tube connector, Velcro closure, artery marker, range check guide.
Display Icons: Systolic/Diastolic/Pulse readings, User indicator, Memory full, Irregular heartbeat, Hypertension, Cuff wrap guide, Low battery, Date/Time.
Prepare device for first use.
Tip: Use AC adapter for prolonged use to conserve batteries.
For most accurate results, measure at same time each day.
WARNING! Do not move or talk during measurement.
Refer to chart below. Consult physician for personal target ranges.
| Category | Systolic (mmHg) | Diastolic (mmHg) |
|---|---|---|
| Normal | Less than 120 | and Less than 80 |
| Elevated | 120-129 | and Less than 80 |
| Hypertension Stage 1 | 130-139 | or 80-89 |
| Hypertension Stage 2 | 140 or higher | or 90 or higher |
| Hypertensive Crisis | Higher than 180 | and/or Higher than 120 |
Icons: Hypertension icon appears if reading is above normal. Irregular heartbeat icon appears if detected.
Stores 100 readings per user (2 users total).
Note: Memory full icon appears when 100 readings are stored for a user.
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not immerse unit or cuff in water. Do not wash cuff in washing machine.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries or use AC adapter. |
| Error Code E1 | Cuff not wrapped correctly | Rewrap cuff, ensure artery marker is aligned. |
| Error Code E2 | Movement during measurement | Remain still and retake measurement. |
| Error Code E3 | Cuff pressure too high | Remove cuff, restart. Check for obstruction. |
| Inconsistent readings | Incorrect posture or timing | Rest 5 minutes, sit correctly, measure at consistent time. |
| Cuff does not inflate | Air tube not connected | Ensure tube is securely connected to unit. |
| Memory full | 100 readings stored | Clear memory or review and delete old readings. |
Reset: Remove batteries and AC adapter for 1 minute to reset unit.
Service: For technical support, visit www.omronhealthcare.com or call 1-800-634-4350.