The Omron BP710N is an automatic upper arm blood pressure monitor with IntelliSense technology for accurate and comfortable readings. It features a wide-range D-Ring cuff, hypertension indicator, irregular heartbeat detection, 60-memory storage with date and time stamp, body movement detection, and an easy-to-read backlit display. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, Wide-range D-Ring Cuff (22-42 cm), AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the optimal level for comfortable measurement |
| Hypertension Indicator | Displays a warning symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays an icon if an irregular rhythm is found during measurement |
| 60-Memory Storage | Stores up to 60 readings with date and time stamp |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| Backlit Display | Easy-to-read LCD screen with illumination |
| D-Ring Cuff | Pre-formed cuff for easy self-application (22-42 cm arm circumference) |
| Date & Time Clock | Built-in clock for accurate time-stamping of readings |
| AC/DC Operation | Powered by 4 AA batteries or included AC adapter |
| Average Reading | Calculates the average of the last 3 readings taken within 10 minutes |
Unpack and verify all items are present.
NOTE: If any item is missing or damaged, contact customer service.
Read all instructions before use.
WARNING! This device is for home use only, not for professional medical diagnosis. Always follow your doctor's instructions regarding blood pressure monitoring.
Display Icons: Hypertension, Irregular Heartbeat, Body Movement, Memory, Average, Battery, AC Power.
Prepare the device for first use.
CAUTION! Do not use rechargeable batteries. Remove batteries if the device will not be used for 3 months or more.
For the most accurate reading, follow these steps carefully.
Tip: Take measurements at the same time each day for consistent tracking.
After a measurement, the display shows:
| Symbol/Value | Meaning |
|---|---|
| Upper Number (e.g., 120) | Systolic Pressure (mmHg) |
| Lower Number (e.g., 80) | Diastolic Pressure (mmHg) |
| Heart Icon with Number (e.g., 72) | Pulse Rate (beats per minute) |
| Flashing Heart Icon | Irregular Heartbeat detected |
| Exclamation Mark (!) in Circle | Hypertension Indicator (reading exceeds 135/85 mmHg) |
| Person Moving Icon | Body Movement detected during measurement |
| Letter 'M' | Memory recall mode is active |
| AVG | Average reading is displayed |
| Battery Icon | Battery level indicator |
| Plug Icon | AC Adapter is connected |
The device stores the last 60 readings with date and time.
Note: Memory is retained even when batteries are removed or replaced.
Proper care ensures long life and accurate readings.
CAUTION! Do not disassemble or attempt to repair the unit. There are no user-serviceable parts inside.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Dead batteries / No power | Insert new batteries or connect AC adapter. Ensure batteries are inserted correctly. |
| Error Code 'E' appears | Cuff not attached / Air leak | Ensure cuff tube is connected securely. Check cuff for holes or cracks. |
| Error Code 'Er1' or 'Er2' | Measurement error | Movement during measurement. Remain still and retry. Ensure cuff is at heart level. |
| Irregular Heartbeat symbol flashes | Irregular rhythm detected | The reading may be less accurate. Take another measurement. If symbol appears frequently, consult your physician. |
| Reading seems too high/low | Incorrect posture or cuff placement | Ensure you are seated correctly, arm supported at heart level, and cuff is snug but not too tight. Wait 5 minutes and retry. |
| Memory does not recall | Memory is empty or cleared | Take a new measurement to store a reading. Check if memory was accidentally cleared. |
Reset: Remove batteries and AC adapter for 1 minute, then reinstall to perform a soft reset.
For technical support, warranty service, or to download this manual:
Visit: www.omronhealthcare.com
Call: 1-800-634-4350