The Omron BP652N is a clinically validated, automatic upper arm blood pressure monitor with IntelliSense technology for comfortable inflation, a wide-range D-Ring cuff (22-42 cm), dual LCD displays, hypertension indicator, irregular heartbeat detector, 200-memory storage with date and time stamp, averaging of last 3 readings, AC adapter compatibility, and WHO classification indicator. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with dual LCD display, D-Ring Cuff, AC Adapter, Storage Case, Instruction Manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Dual LCD Display | Shows systolic, diastolic, pulse, and date/time simultaneously |
| Hypertension Indicator | Displays symbol if reading exceeds WHO hypertension threshold |
| Irregular Heartbeat Detector | Detects and displays symbol for irregular heartbeats during measurement |
| 200-Memory Storage | Stores up to 200 readings with date and time stamp |
| Average of Last 3 Readings | Calculates and displays average of last 3 readings taken within 10 minutes |
| D-Ring Cuff (22-42 cm) | Pre-formed cuff for easy self-application on upper arm |
| WHO Classification Indicator | Color-coded bar graph shows blood pressure level classification |
| AC Adapter Compatible | Can be powered by AC adapter (included) or 4 AA batteries |
| Clock Function | Built-in clock for time and date stamp on stored readings |
Before use, read all instructions carefully.
WARNING! This device is for home use only, not for professional medical diagnosis. Consult your physician for interpretation of readings.
Unpack and verify all items are present.
CAUTION! Do not use if package is damaged or items are missing. Contact retailer or Omron.
Front Panel: START/STOP button, MEMORY button, TIME SET button, Display screen. Cuff: D-Ring, air tube connector, artery mark. Rear: Battery compartment, AC adapter jack.
Display Symbols: Systolic/Diastolic/Pulse readings, Memory number, Date/Time, Battery indicator, Hypertension indicator, Irregular heartbeat symbol, WHO classification bar, Average indicator, Morning/Evening indicator.
Before first use, install batteries or connect AC adapter, set time and date.
Tip: For most accurate readings, use AC adapter or fresh alkaline batteries.
For accurate readings, rest for 5 minutes before measuring, avoid eating, smoking, or exercising 30 minutes prior.
WARNING! Do not move or talk during measurement. Ensure cuff is at heart level.
Memory stores 200 readings with date/time. Press MEMORY button to review.
Note: Memory is maintained when batteries are removed (clock resets).
Clean with soft, dry cloth. Do not immerse in water or use chemicals.
CAUTION! Do not use alcohol or abrasive cleaners. Keep away from electromagnetic sources.
FDA Cleared: KXXXXXX. CE Marked: Medical Device Directive 93/42/EEC. Manufactured for Omron Healthcare, Inc. Copyright © Omron Healthcare, Inc. All rights reserved. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace with fresh batteries or use AC adapter. |
| Error "E" appears | Cuff not attached/leaking | Ensure cuff is connected properly; check for leaks or damage. |
| Inaccurate reading | Incorrect cuff position | Reposition cuff with artery mark over brachial artery; ensure at heart level. |
| Memory not working | Batteries removed too long | Clock resets when batteries removed; memory data remains but time stamp incorrect. |
| Irregular heartbeat symbol | Actual irregular heartbeat or movement | Remain still during measurement; if symbol appears frequently, consult physician. |
| Unit does not inflate | Blocked air tube or weak batteries | Check tube for kinks; replace batteries or use AC adapter. |
Reset: Remove batteries and AC adapter for 5 minutes, then reinstall.
Service: 1-800-634-4350; www.omronhealthcare.com