Omron Blood Pressure Monitor BP5450 Manual

The Omron BP5450 is an advanced upper-arm blood pressure monitor featuring IntelliSense technology for comfortable inflation, a wide-range D-Ring cuff (22-42 cm), dual LCD displays for systolic/diastolic pressure and pulse readings, hypertension detection, morning hypertension indicator, 200 memory storage with date/time stamp, irregular heartbeat detection, body movement detection, and averaging of last 3 readings. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Parts Identification 4. Specifications 5. Initial Setup & Battery Installation 6. Applying the Cuff 7. Taking a Measurement 8. Memory & Data Management 10. Care & Maintenance 11. Regulatory Information 12. Troubleshooting

Features at a Glance

Key components: Main unit with dual LCD displays, D-Ring Cuff with pre-formed tube, AC Adapter port, Memory button, START/STOP button, SET button.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to optimal pressure for comfortable measurement
Dual LCD DisplayShows systolic/diastolic pressure and pulse simultaneously
200 Memory StorageStores readings with date and time stamp for two users (100 each)
Hypertension DetectionIndicator lights up if reading exceeds hypertension threshold
Morning Hypertension IndicatorFlags readings taken in the morning hypertension window
Irregular Heartbeat DetectionDetects and displays symbol for irregular heartbeats during measurement
Body Movement DetectionAlerts if excessive movement is detected during measurement
Average of Last 3 ReadingsCalculates and displays average of last three readings taken within 10 minutes
D-Ring Cuff (22-42 cm)Wide-range cuff for proper fit
AC Adapter CompatibleCan be powered by AC adapter (sold separately) or 4 AA batteries

Safety Information

Read all instructions before use.

  1. Do not use on infants, children, or persons who cannot express themselves.
  2. Do not use during periods of physical restlessness.
  3. Consult physician for proper cuff size if arm circumference is outside 22-42 cm range.
  4. Do not use with a pacemaker or other implanted electronic devices without consulting physician.
  5. For monitoring purposes only; not for diagnosis. Consult physician for interpretation.

WARNING! Do not modify the cuff or tubing. Keep away from children. Do not use near flammable gases.

Parts Identification

Front: LCD Display (shows systolic, diastolic, pulse, indicators), START/STOP Button, Memory Button, SET Button. Side: AC Adapter Jack. Cuff: D-Ring, Air Plug, Artery Marker.

Specifications

Initial Setup & Battery Installation

Before first use, install batteries or connect AC adapter.

  1. Open battery compartment on back of unit.
  2. Insert 4 AA batteries, observing correct polarity (+/-).
  3. Close compartment.
  4. Set date and time: Press SET button, use START/STOP to adjust values, press SET to confirm.
  5. Select user: Press SET to toggle between USER 1 and USER 2.

CAUTION! Use only specified AC adapter. Remove batteries if not using for 3 months or more.

Applying the Cuff

Proper cuff application is essential for accurate readings.

  1. Sit quietly for 5 minutes before measurement.
  2. Remove tight clothing from upper arm.
  3. Insert cuff end through D-Ring to form a loop.
  4. Place cuff on bare arm with artery marker (△) over brachial artery.
  5. Secure cuff 1-2 cm above elbow. Tubing should run down center of arm.
  6. Cuff should be snug; you should be able to insert one finger underneath.
  7. Rest arm on table with palm up, cuff at heart level.

Tip: Take measurements at the same time each day, before exercise, eating, or bathing.

Taking a Measurement

Follow these steps for accurate measurement.

  1. Sit in a chair with feet flat on floor and back supported.
  2. Apply cuff as described above.
  3. Press START/STOP button. All display symbols appear briefly.
  4. Unit inflates automatically. Remain still and quiet during inflation and measurement.
  5. Cuff deflates automatically when measurement is complete.
  6. Reading displays with systolic, diastolic, and pulse values.
  7. Hypertension, irregular heartbeat, or body movement indicators will light if detected.
  8. Press START/STOP to turn unit off, or it will turn off automatically after 1 minute.

WARNING! Do not move or talk during measurement. Do not inflate cuff when not wrapped on arm.

Memory & Data Management

Stores 100 readings each for USER 1 and USER 2.

  1. View memory: Press MEMORY button. Display shows average of last 3 readings.
  2. Press MEMORY again to scroll through individual readings with date/time.
  3. Switch users: While in memory mode, press SET button to toggle between USER 1 and USER 2.
  4. Delete all memory: While in memory mode, press and hold SET button for 3 seconds until "CLR" flashes. Press START/STOP to confirm deletion for current user.

Note: Memory is retained when batteries are removed.

Care & Maintenance

Unplug AC adapter and remove batteries before cleaning.

  1. Clean cuff with mild soap and damp cloth; do not immerse in water.
  2. Clean main unit with dry, soft cloth.
  3. Do not use benzene, thinner, or abrasive cleaners.
  4. Store in cool, dry place away from direct sunlight and extreme temperatures.
  5. Replace cuff if it becomes cracked or damaged.

CAUTION! Do not wash or dry clean the cuff. Do not disassemble the unit.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. CE marked. Medical device classification: Class IIa. Manufacturer: Omron Healthcare, Inc. For support in USA, call 1-800-634-4350 or visit www.omronhealthcare.com.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries with new ones.
Error "E" appearsCuff not connected/leakingEnsure air plug is securely connected. Check cuff for holes.
Error "Er1" appearsMeasurement errorReapply cuff correctly and retry. Remain still during measurement.
Error "Er2" appearsExcessive movementKeep arm still during measurement.
Inconsistent readingsImproper cuff positionEnsure cuff is at heart level. Wait 5 minutes between readings.
Memory not displayingNo stored dataTake a measurement first to store data.
Cuff does not inflateBlocked tubingCheck tubing for kinks. Ensure air plug is fully inserted.

Reset: Remove batteries for 1 minute to reset unit.

Service: 1-800-634-4350; www.omronhealthcare.com