The Omron BP5450 is an advanced upper-arm blood pressure monitor featuring IntelliSense technology for comfortable inflation, a wide-range D-Ring cuff (22-42 cm), dual LCD displays for systolic/diastolic pressure and pulse readings, hypertension detection, morning hypertension indicator, 200 memory storage with date/time stamp, irregular heartbeat detection, body movement detection, and averaging of last 3 readings. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with dual LCD displays, D-Ring Cuff with pre-formed tube, AC Adapter port, Memory button, START/STOP button, SET button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for comfortable measurement |
| Dual LCD Display | Shows systolic/diastolic pressure and pulse simultaneously |
| 200 Memory Storage | Stores readings with date and time stamp for two users (100 each) |
| Hypertension Detection | Indicator lights up if reading exceeds hypertension threshold |
| Morning Hypertension Indicator | Flags readings taken in the morning hypertension window |
| Irregular Heartbeat Detection | Detects and displays symbol for irregular heartbeats during measurement |
| Body Movement Detection | Alerts if excessive movement is detected during measurement |
| Average of Last 3 Readings | Calculates and displays average of last three readings taken within 10 minutes |
| D-Ring Cuff (22-42 cm) | Wide-range cuff for proper fit |
| AC Adapter Compatible | Can be powered by AC adapter (sold separately) or 4 AA batteries |
Read all instructions before use.
WARNING! Do not modify the cuff or tubing. Keep away from children. Do not use near flammable gases.
Front: LCD Display (shows systolic, diastolic, pulse, indicators), START/STOP Button, Memory Button, SET Button. Side: AC Adapter Jack. Cuff: D-Ring, Air Plug, Artery Marker.
Before first use, install batteries or connect AC adapter.
CAUTION! Use only specified AC adapter. Remove batteries if not using for 3 months or more.
Proper cuff application is essential for accurate readings.
Tip: Take measurements at the same time each day, before exercise, eating, or bathing.
Follow these steps for accurate measurement.
WARNING! Do not move or talk during measurement. Do not inflate cuff when not wrapped on arm.
Stores 100 readings each for USER 1 and USER 2.
Note: Memory is retained when batteries are removed.
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not wash or dry clean the cuff. Do not disassemble the unit.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. CE marked. Medical device classification: Class IIa. Manufacturer: Omron Healthcare, Inc. For support in USA, call 1-800-634-4350 or visit www.omronhealthcare.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error "E" appears | Cuff not connected/leaking | Ensure air plug is securely connected. Check cuff for holes. |
| Error "Er1" appears | Measurement error | Reapply cuff correctly and retry. Remain still during measurement. |
| Error "Er2" appears | Excessive movement | Keep arm still during measurement. |
| Inconsistent readings | Improper cuff position | Ensure cuff is at heart level. Wait 5 minutes between readings. |
| Memory not displaying | No stored data | Take a measurement first to store data. |
| Cuff does not inflate | Blocked tubing | Check tubing for kinks. Ensure air plug is fully inserted. |
Reset: Remove batteries for 1 minute to reset unit.
Service: 1-800-634-4350; www.omronhealthcare.com