The Omron Blood Pressure Monitor 7450 is an automatic, upper-arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate and comfortable inflation, a large display with backlight, hypertension indicator, irregular heartbeat detection, memory storage for multiple users, and a WHO blood pressure classification indicator. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with display, Arm cuff, AC adapter, Storage case, Instruction manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for accurate and comfortable measurement |
| Large LCD Display with Backlight | Easy-to-read results in various lighting conditions |
| Hypertension Indicator | Alerts if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Dual User Memory | Stores up to 100 readings per user (200 total) |
| WHO Classification Indicator | Shows blood pressure category based on WHO guidelines |
| Date & Time Stamp | Records measurement date and time for tracking |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
| AC Adapter Operation | For continuous use without batteries |
| Automatic Power Off | Conserves battery life |
Read all instructions before use. For accurate measurements and safe operation.
WARNING! This device is for home use only, not for professional medical diagnosis. Consult your doctor for interpretation of readings.
Main Unit: START/STOP button, MEMORY button, USER button, Display screen. Arm Cuff: Tube connector, cloth cuff with metal ring, Velcro closure. AC Adapter: Input 100-240V AC, Output 6V DC.
Prepare the monitor for first use.
CAUTION! Do not use if cuff is damaged. Ensure tube is not twisted or pinched.
For most accurate results, measure at the same time each day.
Tip: Avoid eating, smoking, or drinking caffeine 30 minutes before measurement.
Store and recall past readings for two users (User 1 and User 2).
Refer to WHO classification for blood pressure levels.
| Symbol | Meaning |
|---|---|
| SYS (mmHg) | Systolic pressure (pressure when heart contracts) |
| DIA (mmHg) | Diastolic pressure (pressure when heart relaxes) |
| Pulse (bpm) | Heart rate in beats per minute |
| Irregular Heartbeat Icon | Appears if irregular rhythm detected during measurement |
| Hypertension Indicator | Appears if systolic ≥135 or diastolic ≥85 mmHg |
| WHO Bar Indicator | Shows category: Normal, Prehypertension, Hypertension |
Note: Single readings may vary. Track trends over time and consult your physician.
Proper care ensures accuracy and longevity.
CAUTION! Do not immerse monitor or cuff in water. Do not disassemble the unit.
FDA Cleared: KXXXXXX. Manufactured for Omron Healthcare, Inc. CE Mark: Complies with European Medical Device Directive. This device complies with Part 15 of the FCC Rules. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries; ensure correct polarity. |
| Error Code E1 | Cuff not attached or leaking | Check cuff connection; ensure cuff is properly applied. |
| Error Code E2 | Excessive movement during measurement | Remain still and retry measurement. |
| Inconsistent readings | Incorrect cuff position or posture | Apply cuff correctly at heart level; sit with back supported. |
| Memory not storing | Memory full or user not selected | Clear memory; press USER button to select correct user before measuring. |
| Pulse reading erratic | Irregular heartbeat or poor circulation | Consult your physician if irregular heartbeat symbol appears frequently. |
Reset: Remove batteries and AC adapter for 1 minute, then reinsert.
Service: 1-800-634-4350; www.omronhealthcare.com