The Omron Blood Pressure Monitor 3 Series is a clinically validated, automatic upper arm blood pressure monitor designed for home use. It features IntelliSense technology for accurate and comfortable inflation, detects irregular heartbeats, stores readings for multiple users, includes a hypertension indicator, and has a large, easy-to-read display. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the ideal level for accurate and comfortable measurement |
| Irregular Heartbeat Detection | Detects and displays an irregular heartbeat symbol during measurement |
| Dual User Memory | Stores up to 100 readings for two users (User A & User B) |
| Hypertension Indicator | Displays a warning symbol if systolic/diastolic readings are high |
| Large LCD Display | Easy-to-read backlit screen showing systolic, diastolic, pulse, and date/time |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| AC Adapter Compatible | Can be powered by AC adapter (included) or 4 AA batteries |
| Comfortable Cuff | Pre-formed 22-32 cm arm cuff for a secure fit |
| Date & Time Stamp | Records the date and time with each reading for tracking |
| AVG (Morning Average) | Calculates and displays the average of your last 3 morning readings |
Read all instructions before use. For personal use only.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician for interpretation of readings.
Insert batteries or connect AC adapter. Set date and time.
CAUTION! Use only the specified AC adapter. Do not mix old and new batteries.
Front Panel: START/STOP button, MEMORY button, CLOCK button.
Display Symbols: User A/B icon, Memory Full icon, Irregular Heartbeat symbol, Hypertension Indicator, Battery icon, Date/Time, Systolic/Diastolic/Pulse readings, AVG (Average) icon.
Memory: Press MEMORY to review stored readings. Use START/STOP to scroll between User A and User B memories. Press and hold MEMORY to delete all readings for the current user.
For the most accurate reading, rest for 5 minutes before measuring. Avoid caffeine, exercise, and smoking 30 minutes prior.
Tip: Take measurements at the same time each day, such as morning and evening, for consistent tracking.
Stores 100 readings for each of two users (User A and User B).
Unplug AC adapter and remove batteries before cleaning.
CAUTION! Do not attempt to disassemble or repair the monitor. There are no user-serviceable parts inside.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This equipment has been tested and found to comply with the limits for a Class B digital device. CE marked. Manufactured for Omron Healthcare, Inc. For support in the US and Canada, visit www.omronhealthcare.com or call 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Dead batteries, improper AC adapter connection | Replace batteries. Ensure AC adapter is firmly connected to monitor and wall outlet. |
| Error Code "E" appears | Cuff not attached, air leak, or cuff wrapped too loosely | Ensure cuff is connected securely. Re-wrap cuff snugly. Check tube for damage. |
| Irregular Heartbeat symbol flashes | Irregular rhythm detected during measurement | Remain still and take another measurement. If symbol appears frequently, consult your physician. |
| Readings seem inconsistent or inaccurate | Incorrect body position, recent activity, talking/moving during measurement | Rest for 5 minutes. Ensure proper sitting posture and cuff position at heart level. Remain still and quiet. |
| Memory is full | 100 readings stored for the current user | Delete old readings or switch to the other user profile to continue storing. |
| Cuff does not inflate | Blocked air tube, weak batteries | Check that air tube is not kinked. Replace batteries. |
Reset: Remove batteries and AC adapter for 1 minute to reset the microprocessor.
Service: For service, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com.