The Omron BP742N is a fully automatic upper arm blood pressure monitor with IntelliSense technology for accurate and comfortable readings. It features a large, easy-to-read display, hypertension indicator, irregular heartbeat detector, 60-memory storage with date and time, and a wide-range D-Ring cuff (22-42 cm). Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit, D-Ring Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to the optimal level for comfortable measurement |
| Hypertension Indicator | Displays warning symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detector | Detects pulse irregularities during measurement |
| 60-Memory Storage | Stores readings with date and time for two users (30 each) |
| Large LCD Display | Easy-to-read backlit screen with clear icons |
| D-Ring Cuff (22-42 cm) | Wide-range cuff for a proper fit on most arms |
| One-Touch Operation | Simple START/STOP button for easy use |
| AC Adapter/Battery Operation | Powered by 4 AA batteries or included AC adapter |
| Average Reading | Calculates the average of the last 3 readings taken within 10 minutes |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
Read all instructions before use.
WARNING! This device is not intended to treat or diagnose medical conditions. Use only as directed.
Front: LCD Display, START/STOP Button, Memory Button, User Select Button (1/2). Rear: Battery Compartment, AC Adapter Jack. Cuff: D-Ring, Air Tube, Metal Hook.
Insert batteries or connect AC adapter. Set date and time.
CAUTION! Use only specified AC adapter. Do not mix old and new batteries.
For accurate readings, sit quietly for 5 minutes before measuring.
Tip: Take measurements at the same time each day for consistent tracking.
Refer to the blood pressure classification chart (included in manual). Hypertension Indicator: Symbol appears if systolic ≥135 mmHg or diastolic ≥85 mmHg. Irregular Heartbeat Symbol: Appears if irregular rhythm detected during measurement—consult physician if frequent.
Clean with soft, dry cloth. Do not immerse in water or use solvents.
CAUTION! Do not disassemble or attempt repairs. No user-serviceable parts inside.
| Display | Meaning | Action |
|---|---|---|
| E1 | Cuff not properly attached or air leakage | Reattach cuff securely; check tube connections |
| E2 | Excessive movement during measurement | Remain still and retake measurement |
| E3 | Pulse signal too weak or irregular | Reposition cuff; relax and retry |
| E5 | Memory full | Clear memory or overwrite old readings |
| Lo | Low battery | Replace all batteries or use AC adapter |
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries, improper insertion | Replace batteries; ensure correct polarity. |
| Inaccurate reading | Improper cuff placement, movement | Reposition cuff correctly; remain still during measurement. |
| Cuff does not inflate | Air leak, tube blockage | Check cuff and tube for damage; secure connections. |
| Error code displayed | See Error Messages section | Refer to section 10 for specific error resolution. |
| Memory not storing | Memory full, user not selected | Clear memory; select User 1 or 2 before measuring. |
Reset: Remove batteries and AC adapter for 1 minute to reset unit.
Service: For service, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com.