Omron Blood Pressure Instruction Manual

The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm device designed for accurate at-home blood pressure and pulse rate measurement. It features IntelliSense technology for comfortable inflation, hypertension detection indicators, a large LCD display with backlight, memory storage for multiple users, irregular heartbeat detection, body movement detection, and AC adapter compatibility. Below are key sections for safety, features, setup, measurement, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Parts Identification 4. Initial Setup & Battery Installation 5. Applying the Cuff 6. Taking a Measurement 7. Understanding the Display 8. Memory Function 9. Care & Maintenance 10. Specifications 11. Troubleshooting

Features at a Glance

Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.

FeatureDescription
IntelliSense TechnologyAutomatically inflates to the optimal level for comfortable measurement
Hypertension IndicatorDisplays symbol if systolic/diastolic readings are in hypertension range
Irregular Heartbeat DetectionDetects and displays symbol for pulse irregularities during measurement
Dual User MemoryStores up to 100 readings per user (User 1 & User 2)
Body Movement DetectionAlerts if excessive movement is detected during measurement
Large LCD with BacklightEasy-to-read display for readings, date, time, and indicators
AVERAGE ModeCalculates the average of the last 3 readings taken within 10 minutes
Cuff Wrapping GuideEnsures proper cuff application for accurate results
AC Adapter PortFor use with optional AC adapter (not for use with batteries)
START/STOP ButtonInitiates and stops the measurement process

Safety Information

Read all instructions before use. For personal home use only.

  1. Do not use on infants, children, or persons who cannot express themselves.
  2. Do not use for self-diagnosis or to alter medication without consulting a physician.
  3. Do not use during bathing or showering.
  4. Do not disassemble or modify the device.
  5. Keep the device away from strong electromagnetic fields (e.g., microwave ovens, mobile phones).

WARNING! This device is not a toy. Keep out of reach of children. Do not use on an injured or sore arm. Consult your doctor if readings are consistently abnormal.

Parts Identification

Familiarize yourself with the main components.

  1. Main Unit: Contains display, control buttons, and air hose connector.
  2. Arm Cuff: Includes D-ring, cloth wrap, and air tube. Cuff circumference range: 22-42 cm.
  3. AC Adapter Jack: Located on the side of the main unit.
  4. Battery Compartment: Holds 4 AA batteries (located on the bottom).
  5. Display: Shows systolic/diastolic pressure, pulse, date, time, user indicator, and error symbols.

CAUTION! Use only the provided cuff or an Omron-approved replacement cuff. Using an incorrect cuff may result in inaccurate readings.

Initial Setup & Battery Installation

Power on the device; set date and time.

  1. Install Batteries: Open battery compartment, insert 4 new AA batteries observing polarity, close cover.
  2. Set Date/Time: Press the CLOCK button. Use the MEMORY button to select value and START/STOP to adjust. Press CLOCK to confirm.
  3. Select User: Press the USER button to toggle between User 1 and User 2 for memory storage.
  4. Connect AC Adapter (Optional): Plug adapter into jack on unit and into wall outlet. Unit will operate on AC power; batteries are not used.

CAUTION! Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.

Applying the Cuff

Tip: The cuff should be tight enough that only one finger fits between cuff and arm. Do not roll up tight sleeves.

Taking a Measurement

Remain still and quiet during measurement.

  1. Press the START/STOP button. All display symbols will appear briefly.
  2. The cuff will inflate automatically. The monitor determines the proper inflation level.
  3. As the cuff deflates, your systolic pressure, diastolic pressure, and pulse rate are measured and displayed.
  4. Measurement is complete when cuff deflates fully. Press the START/STOP button to turn the unit off.
  5. The reading is automatically stored in memory for the selected user.

WARNING! Do not move your arm or body during measurement. Do not inflate the cuff when it is not wrapped around your arm.

Understanding the Display

Access OSD via TV MENU or SETUP (DVD). Front Panel: POWER, OPEN/CLOSE, AUTO/DPMS, MUTE.

Symbols:

Memory Function

Stores up to 100 readings for each of two users.

  1. View Memory: Press the MEMORY button. The most recent reading appears with a "M" symbol.
  2. Scroll: Press MEMORY again to scroll through previous readings. The display shows reading number, values, date, and time.
  3. View Average: While in memory mode, press and hold the MEMORY button for 3 seconds to display the average of the last 3 readings taken within 10 minutes.
  4. Clear Memory: To clear all memory for the current user, remove all batteries, wait 1 minute, then reinstall batteries while holding down the MEMORY button.

Tip: Take measurements at the same time each day for consistent tracking.

Care & Maintenance

Unplug adapter and remove batteries before cleaning. Use a soft, dry cloth only; do not use solvents or abrasives.

  1. Cuff: Wipe with a damp cloth and mild detergent. Do not machine wash, iron, or dry clean. Allow to air dry completely.
  2. Main Unit: Wipe exterior with dry cloth. Do not submerge in water.
  3. Storage: Store in the provided case in a cool, dry place away from direct sunlight, extreme temperatures, dust, and humidity.

CAUTION! Do not wash or immerse the main unit or air tube in water. Do not bend or twist the air tube excessively.

Specifications

Troubleshooting

SymptomPossible CauseCorrective Action
Display is blankDead batteries / No powerInstall new batteries or connect AC adapter. Ensure battery polarity is correct.
Error Symbol "E" appearsCuff not applied correctly / MovementRe-wrap cuff correctly. Remain still and retry measurement.
Irregular Heartbeat Symbol flashesPulse irregularity detectedRemain calm and retry. If symbol appears frequently, consult your doctor.
Readings seem inconsistent or highIncorrect posture / Recent activityRest for 5 minutes, sit correctly with cuff at heart level, and retry. Avoid talking.
Memory does not store readingsMemory full / Wrong user selectedClear memory for current user or switch to the correct user before measuring.
Cuff does not inflateAir leak / Blocked tubeCheck cuff wrap and connections. Ensure air tube is not kinked.

Reset: Remove batteries and AC adapter for 1 minute to perform a soft reset.

Service: For service or support, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com. Do not attempt to repair the unit yourself.