The Omron Blood Pressure Cuff is a clinically validated, automatic upper arm monitor designed for accurate at-home blood pressure and pulse measurement. It features IntelliSense technology for comfortable inflation, irregular heartbeat detection, hypertension indicator, body movement detection, memory storage for multiple users, and a large backlit display. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter (if applicable), Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation level for comfortable measurement |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Hypertension Indicator | High blood pressure warning symbol |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Memory Storage | Stores readings for multiple users (e.g., 2 users x 100 readings) |
| Large Backlit Display | Easy-to-read LCD with backlight for low-light conditions |
| Date & Time Stamp | Records measurement date and time for tracking |
| Average Reading | Calculates average of last 3 readings taken within 10 minutes |
| Cuff Wrap Guide | Indicates proper cuff placement |
| AC Adapter Port | For optional AC adapter connection (battery operation primary) |
Read all instructions before use. Keep for future reference.
WARNING! This device is not a substitute for professional medical diagnosis. Consult your physician for interpretation of readings.
Front Panel: START/STOP Button, Memory Button, User Button (1/2), Power Adapter Port.
Display Symbols: Systolic Pressure, Diastolic Pressure, Pulse Rate, Irregular Heartbeat Symbol, Hypertension Indicator, Body Movement Symbol, User Indicator, Memory Full Icon, Battery Level, Date/Time.
Cuff: Arm tube, Cloth wrap, Metal D-ring, Air tube, Cuff wrap guide (marked range).
Prepare the monitor for first use.
CAUTION! Ensure cuff is the correct size for your arm circumference. Using wrong size affects accuracy.
For most accurate results, measure at the same time each day.
Tip: Wait at least 3 minutes between measurements on the same person.
Refer to the provided blood pressure classification chart. Consult your physician with your readings.
Stores readings with date and time for two users.
Note: Memory is retained when batteries are removed.
Unplug AC adapter (if used) and remove batteries before cleaning.
CAUTION! Do not disassemble or attempt to repair the unit. No user-serviceable parts inside.
Uses 4 AA alkaline batteries (included for demo, may not be full capacity).
WARNING! Risk of explosion if battery is replaced incorrectly. Replace only with same or equivalent type.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new ones. |
| Error Code "E" | Cuff not wrapped correctly / movement | Re-wrap cuff snugly. Remain still and retry. |
| Inaccurate reading | Wrong cuff position / talking or moving | Ensure cuff is at heart level. Sit quietly for 5 min before measuring. |
| Cuff does not inflate | Air tube leak / blockage | Check tube connections. Ensure tube is not kinked. |
| Irregular Heartbeat symbol flashes | Possible arrhythmia detected | Consult your physician with your readings. |
| Memory not working | Memory is full / button error | Clear memory or select correct user. Ensure button is pressed firmly. |
Reset: Remove batteries for 1 minute to reset the unit.
Service: For service, contact Omron Healthcare at 1-800-634-4350 or visit www.omronhealthcare.com.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference.