The Omron Blood Pressure Cuff is a clinically validated, automatic upper arm blood pressure monitor designed for home use. It features IntelliSense technology for comfortable inflation, hypertension indicator, irregular heartbeat detection, memory storage for multiple users, body movement detection, and a large LCD display with backlight. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for comfortable measurement |
| Hypertension Indicator | Displays warning symbol if reading is high |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Dual User Memory | Stores up to 100 readings per user (200 total) |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Large LCD with Backlight | Easy-to-read display for day or night use |
| Date & Time Stamp | Records date and time with each reading |
| Average Reading | Calculates average of last 3 readings |
| Cuff Wrap Guide | Visual indicator for proper cuff placement |
| AC Adapter Compatible | Can be powered by AC adapter (sold separately) |
Read all instructions before use. Consult your physician for proper blood pressure management.
WARNING! This device is not a substitute for professional medical diagnosis. Always consult your physician about your blood pressure readings.
Front Panel: START/STOP Button, Memory Button, User Button (User 1/User 2), Power Button. Display: Systolic Pressure, Diastolic Pressure, Pulse Rate, Date/Time, User Indicator, Battery Indicator, Error Symbols. Cuff: Arm Tube, Metal Ring, Cloth Hook, Air Plug.
CAUTION! Ensure cuff is the correct size for your arm circumference (22-42 cm). Using wrong size may give inaccurate readings.
Before first use: Install batteries and set date/time.
Tip: For most accurate readings, wait at least 30 minutes after eating, smoking, or exercising.
For consistent results, measure at the same time each day.
WARNING! Do not move or talk during measurement. Do not inflate cuff when not wrapped on arm.
Note: American Heart Association categories: Normal (<120/<80), Elevated (120-129/<80), Hypertension Stage 1 (130-139/80-89), Hypertension Stage 2 (≥140/≥90).
Stores 100 readings per user with date/time stamp.
Tip: Take readings at the same time daily for most accurate tracking.
Unplug AC adapter (if used) and remove batteries before cleaning.
CAUTION! Do not autoclave, boil, or sterilize with chemicals. Do not bend tubing sharply.
WARNING! Do not mix old and new batteries. Do not mix alkaline with other types. Remove batteries if not using for extended period.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with fresh ones. |
| Error E1 | Cuff not wrapped properly | Rewrap cuff correctly and restart measurement. |
| Error E2 | Excessive movement | Remain still and restart measurement. |
| Error E3 | Irregular heartbeat detected | Wait 5 minutes and retry. Consult physician if frequent. |
| Error E5 | Cuff over-inflated | Deflate completely and restart measurement. |
| Inconsistent readings | Wrong cuff position | Ensure cuff is at heart level and properly positioned. |
| Memory not storing | Memory full | Clear memory or switch to other user memory. |
| Cuff leaks air | Cracked tubing or loose connection | Check connections; replace cuff if damaged. |
Reset: Remove batteries for 5 minutes to reset device.
For support, visit www.omronhealthcare.com or contact 1-800-634-4350.