The Omron 7350 is an upper arm blood pressure monitor with IntelliSense technology for accurate, comfortable measurement. It features a wide-range D-Ring cuff (22-42 cm), hypertension indicator, irregular heartbeat detection, 100 memory storage with date/time stamp, averaging of last 3 readings, morning hypertension indicator, and AC adapter compatibility. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with display, D-Ring cuff, AC adapter port, START/STOP button, Memory button.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts cuff inflation for comfortable measurement |
| Hypertension Indicator | Displays symbol if systolic/diastolic readings are high |
| Irregular Heartbeat Detection | Detects pulse irregularities during measurement |
| 100 Memory Storage | Stores readings with date and time stamp |
| 3-Time Average | Calculates average of last 3 readings taken within 10 minutes |
| Morning Hypertension Indicator | Flags readings taken in morning hours (6am-10am) |
| D-Ring Cuff (22-42cm) | Pre-formed cuff for easy self-application |
| AC Adapter Compatible | Can operate on 4 AA batteries or AC adapter (sold separately) |
| Large Display | Easy-to-read LCD with backlight |
| Date/Time Clock | Automatic timestamp for all readings |
Read all instructions before use. Not a medical device for diagnosis.
WARNING! Do not modify cuff or tubing. Do not disassemble unit. Keep batteries away from children.
Front Panel: Display, START/STOP button, Memory button. Side: AC adapter port. Cuff: D-Ring, air tube, metal hook, index line.
CAUTION! Ensure cuff is correct size for your arm. Using wrong size affects accuracy.
Insert batteries or connect AC adapter, set date/time.
Tip: For most accurate readings, measure at same time each day before medication or eating.
100 memory slots with date/time. Memory full overwrites oldest reading.
View Memory: Press Memory button to scroll through readings. Display shows memory number, systolic/diastolic, pulse, date/time, morning indicator.
3-Time Average: Take 3 readings within 10 minutes. Average displays automatically after third reading.
Clear Memory: Remove batteries for 1 minute to clear all memory (date/time resets).
Display symbols and their meanings:
Tip: Consult physician to establish your personal target ranges. Multiple readings over time provide best trend analysis.
Clean with soft, dry cloth. Do not immerse in water.
CAUTION! Do not use alcohol, benzene, or abrasive cleaners. Do not disassemble unit.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 AA batteries with new ones. |
| Error E1 | Cuff not attached properly | Ensure cuff connector is fully inserted. |
| Error E2 | Cuff pressure error | Check cuff for leaks or improper wrapping. |
| Inaccurate reading | Wrong cuff position | Center cuff over brachial artery at heart level. |
| Memory not storing | Memory full | Memory overwrites oldest; consider recording readings elsewhere. |
| Irregular heartbeat symbol frequent | Actual arrhythmia or movement | Remain still during measurement; consult physician if persistent. |
Reset: Remove batteries for 1 minute to reset unit (clears memory).
Omron 7350 includes 5-year warranty from date of purchase. Register product online at www.omronhealthcare.com. For technical support, contact Omron Healthcare at 1-800-634-4350 or [email protected]. For accurate use, have device validated annually by qualified service center.
Disposal: Dispose according to local regulations. Remove batteries for separate disposal.